Teryair 59 04 81 Operation And Maintenance Manual Download Page 25

FF-MM-300-REV - 00

Page 25

Operation and Maintenance Guide  Pneumatic Needle Scalers

Warranty Certificate 

 

Every product manufactured by Teryair 

 is built to meet the highest standards of quality. 

Teryair warrants that the Products, accessories and parts manufactured or supplied 

by the company be free from defects in material and workmanship for a period of six 

months from date of Teryair authorized dealer invoice to customer, or one year from 

date of Teryair invoice to dealer, whichever is earlier. Failure due to normal wear, 

misapplication, or abuse is, of course, excluded from this warranty. 

Since the use of Teryair products and parts is beyond our control, Teryair cannot 

guarantee the suitability of any product or part for a particular application and Teryair 

shall not be liable for any consequential damage or expense arising from the use or 

misuse of its products on any application. Teryair does not warranty bought out 

products or components such as electric motors and hardware but will assist in 

directing warranty queries to the dealer/manufacturer responsible. Teryair 

responsibility is limited solely to replacement or repair of defective Teryair products 

or components. 

Dealer/End User shall have no right or remedy and Teryair shall have no liability or obligation under the warranty, if: 

(i) a Product is altered, changed, modified or tampered with in any way, (ii) a Product is damaged after deposit with the

transporter for shipment; (iii) a Product is not properly preserved, packaged, stored, processed or handled after receipt; (iv) a 

Product is not used and maintained in accordance with Teryair's recommended operating and maintenance manuals, 

instructions and procedures, if any; (v) a Product is not properly incorporated or installed in, or not properly combined with, an 

Other Product; (vi) the issue with a Product is directly or indirectly attributable to, or directly or indirectly results from or arises

out of, a failure, substandard performance or other issue with another product, material, component or part not supplied by 

Teryair; (vii) the issue with a Product is directly or indirectly attributable to, or directly or indirectly results from or arises out of, 

compliance with any design, specification or other specific requirement of Dealer/End User; (viii) a Product is used in a manner, 

with a substance or for a purpose other than the normal manner, substance and purpose for which it is intended or is otherwise

subjected to abnormal use or service; (ix) a Product is subjected to a power surge, brown out or other similar occurrence; (x) 

the issue with a Product is directly or indirectly attributable to, or directly or indirectly results from or arises out of, normal wear 

and tear of such Product (including, without limitation, things such as worn seals, diaphragms, balls, O rings, gaskets, chisels,

cutters, hoses and other such wearing components; (xi) the issue with a Product is directly or indirectly. 

Dated 

Product Model Number 

Product Serial Numbar 

   Ajay Bhagat, Q.A. Manager 

  (Company Seal) 

Summary of Contents for 59 04 81

Page 1: ...SN39PGVL Pistol Grip Pneumatic Needle Scalers 59 05 00 SN45PGVL Pistol Grip Pneumatic Needle Scalers 59 05 10 Read this manual carefully before installing operating or servicing this equipment It s t...

Page 2: ...for SN24PG 10 Exploded View for SN24PG 11 Diassembly and Re assembly for SN29PG 12 Exploded View for SN29PG 13 Bill of Materials for SN29PG 14 Diassembly and Re assembly for S39PGVL 15 Bill of Materia...

Page 3: ...00 4 0 11 2400 90 7 2 75 2 7 1 4 3mm x 19 Nos SN45PGVL 59 05 10 5 5 0 16 3000 109 5 2 3 3 5 1 4 3mm x 28 nos Warning This manual must be read and the operating instructions carefully followed Warning...

Page 4: ...edle Scaler is not designed for use in an explosive environment Caution Completely turn off the Pneumatic Needle Scaler and disconnect air supply line before attempting any service Read Assembly and D...

Page 5: ...ible mention the serial number of the Pneumatic Needle Scaler when ordering spares Use genuine Teryair spares and if pos sible mention the serial number of the Pneumatic Needle Scaler when ordering sp...

Page 6: ...FF MM 300 REV 00 Page 6 Operation and Maintenance Guide Pneumatic Needle Scalers 6 7 1 2 3 14 4 5 8 9 10 12 13 11 15 16 17 19 18 20 Exploded View for SN24ST...

Page 7: ...ING VALVE CAP 1 8 100 51 14 VALVE SPRING 1 9 100 25 11 VALVE STEM 1 10 124 40 01 O RING VALVE SEAT 1 11 100 30 12 THROTTLE LEVER 1 12 100 50 19 ROLL PIN 3 17 x 25 26 1 13 100 40 18 PLASTIC PLUG 1 14 1...

Page 8: ...ew Cylinder 1 from Cover Assem bly 6 Now remove Piston 4 O ring 3 O ring 2 from Cylinder 1 and replace it with new ones If found dam aged worn out e Unscrew Valve Body 7 from Cover Assem bly 6 remove...

Page 9: ...1 8 100 21 06 VALVE CAP 1 9 100 40 15 O RING VALVE CAP 1 10 100 51 14 VALVE SPRING 1 11 100 25 11 VALVE STEM 1 12 124 40 01 O RING VALVE SEAT 1 13 100 30 12 THROTTLE LEVER 1 14 100 50 19 ROLL PIN 1 15...

Page 10: ...FF MM 300 REV 00 Page 10 Operation and Maintenance Guide Pneumatic Needle Scalers Exploded View for SN24PG 21 18 19 20 17 22 16 6 4 2 3 1 5 13 8 9 10 11 12 7 15 14...

Page 11: ...nes If found damaged worn out e Unscrew Cylinder 2 from Cover Assem bly 1 Now remove O ring 4 O ring 20 and Piston 3 from Cylinder 2 and replace it with new ones f Unscrew Valve Body 19 from Cover Ass...

Page 12: ...FF MM 300 REV 00 Page 12 Operation and Maintenance Guide Pneumatic Needle Scalers Exploded View for SN29PG 13 20 19 18 12 15 14 17 22 21 4 3 2 8 10 9 5 7 11 6 1 16...

Page 13: ...ANVIL 1 9 100 21 05 NEEDLE HOLDER 3 1 10 022 90 04BL NEEDLE 3 X 180 28 11 200 90 68 CAP HEAD SCREW 2 12 100 25 11 VALVE STEM 1 13 100 25 06 VALVE CAP 1 14 100 51 14 VALVE SPRING 1 15 100 40 15 O RING...

Page 14: ...e Remove O ring 4 from Guide Plate 2 Now remove Ball Retaining O ring 7 and Ball 8 from Cylinder 6 and replace it with new ones If found damaged worn out f Unscrew Valve Body 21 from Cover As sembly...

Page 15: ...ISTON RING 1 12 136 24 06 INTERMEDIATE TUBE 1 13 136 40 10 PISTON CUSHION 1 14 136 21 05 NEEDLE HOLDER 3MM 1 15 022 90 04HTBL NEEDLE 3 X 180 19 16 136 40 12 INSERT FOR FRONT TUBE 1 17 100 40 13 O RING...

Page 16: ...FF MM 300 REV 00 Page 16 Operation and Maintenance Guide Pneumatic Needle Scalers Exploded View for SN39PGVL 1 19 22 18 16 12 13 20 14 15 10 9 11 6 8 7 5 4 2 3 17 23 24 27 25 26 21 29 28...

Page 17: ...Intermediate Tube 21 from Cover Assembly 1 e Remove O ring 27 from Guide Plate 4 remove Ball Retaining O ring 6 and Ball 3 from Cylinder 5 Replace parts with new ones If found damaged worn out f Unscr...

Page 18: ...R STEM REACTION RING 1 11 136 21 04 PISTON 1 12 136 36 08 PISTON RING 1 13 136 40 10 PISTON CUSHION 1 14 148 50 21 VALVE PIN 1 15 136 21 05 NEEDLE HOLDER 3MM 1 16 022 90 04HTBL NEEDLE 3 X 180 19 17 10...

Page 19: ...FF MM 300 REV 00 Page 19 Operation and Maintenance Guide Pneumatic Needle Scalers Exploded View for SN39STVL 24 23 26 21 22 15 16 11 12 14 13 5 10 3 6 4 7 27 2 25 1 20 18 8 17 9 19...

Page 20: ...g 10 from Guide Plate 4 remove Ball Retaining O ring 3 and Ball 2 from Cylinder 6 to replace it with new ones If found damaged worn out f Unscrew Valve Body 21 from Cover Assembly 20 g Remove Rubber G...

Page 21: ...LE HOLDER 3mm 1 14 022 90 04HTBL NEEDLE 3 X 180 FOR NEEDLE SCALER 28 15 148 51 22 FRONT SPRING 1 16 148 5119 INSERT 1 17 148 24 09 FRONT TUBE 1 18 148 40 20 CYLINDER STEM REACTION RING 1 19 148 50 21...

Page 22: ...FF MM 300 REV 00 Page 22 Operation and Maintenance Guide Pneumatic Needle Scalers Exploded View for SN45PGVL 7 6 11 2 17 19 16 12 3 15 10 9 18 8 4 5 20 14 27 13 1 21 26 28 29 25 24 23 22...

Page 23: ...d in accordance with our standard test procedures and meets the specifications for material and performance values as published in our literature We further certify that the product has been given our...

Page 24: ...ng European Directives 2006 42 EC Machinery Safety and Har monized standards ISO 12100 1 2010 Safety of Machinery general Principles for Design Risk Assessment and Risk Reduction Registered Office 416...

Page 25: ...d after deposit with the transporter for shipment iii a Product is not properly preserved packaged stored processed or handled after receipt iv a Product is not used and maintained in accordance with...

Page 26: ...FF MM 300 REV 00 Page 26 Operation and Maintenance Guide Pneumatic Needle Scalers This page is intentionally Left blank...