OFF
ON
COLD WATER IN
SAO SOLUTION OUT
OFF
ON
COLD WATER IN
SAO SOLUTION OUT
SAO Dispenser
Cartridge
122cm
48”
HEIGHT RECOMMENDATION
SAO DISPENSER
INSTALLATION GUIDE
www.tersano.com
··
1-800-727-8835
US and International Patents and Patents Pending.
*Above diagram is a representation only
NOTE
• Tersano is not responsible for ANY damages if the Tersano unit is not installed as instructed in the steps above and/or if
water is left on to the dispenser while not in use or being attended.
• Unit to be installed vertically as shown in the picture above never horizontally. Doing so will damage the unit.
• The new hose-sets supplied with the appliance are to be used, old hose-sets should not be reused.
• Failure to follow the above installation instructions will void the warranty.
1. For correct installation, choose a location where both
the dispensing box and cartridge tube will be affixed
directly over a sink or a floor drain.
2. Carefully remove all of the items from the cartons.
3. Remove mounting hardware and mounting template
from plastic packages.
4. Affix the mounting template to the wall with tape. Drill
the holes in the wall where indicated on the template.
5. Insert the #12 anchors into the 4 holes drilled for the
dispenser. Attach the dispenser to the wall using the four
#12 - 1 ½” wallmount screws in the top and bottom.
Not
to be mounted on mobile devices, hand carts, etc.
6. Insert the #8 anchors into the two holes drilled for the
cartridge bracket. Attach the cartridge bracket to the wall
using the two #8 - 1 ½ “ screws.
7. Once brackets are mounted, hang the cartridge and insert
the blue desiccant filter into the front of the dispenser
until it snaps into place.
8. Facing the cartridge, attach the quick disconnect end to
the blue color fitting on the bottom left side connection
of the cartridge. Attach the opposite end (the white
pressure regulator) of the hose onto the cold water supply
(3/8” hose bibb).
9. Attach connector hose (with the screen filter) supplied to
the right side outlet on the cartridge and attach opposite
end to
COLD WATER IN
on the dispenser (white color
fittings into grey).
10. Ensure that the water flow is at minimum 4L/minute.
This can be checked with a simple water pressure testing
gauge available at most hardware stores. NOTE: If greater
than 65 PSI, a water pressure regulator will be required.
11. Attach hose with yellow handle to
SAO SOLUTION OUT
on the dispenser’s barbed fitting - clamp is not required.
12. Connect only to a circuit that is protected by a
ground-fault circuit-interrupter (GFCI).
INSTALLATION INSTRUCTIONS
FOR INDOOR WALL MOUNT & DRY LOCATIONS ONLY
07/2020
Desiccant Filter
SAO SOLUTION OUT
hose
(182.88cm/72
”
)
FLOW OFF/ON
Switch
Performance Indicators
Service Light
SAO DISPENSER
CARTRIDGE
3.8cm
1.5”
10.8cm
4.25”
35.56cm
14”
57.15cm
22.5”
15.24cm
6”
6.35mm
(1/4”)
Drill Bit
6mm X 38mm
(#12 X 1 1/2”)
Hex Head
4mm
(3/16”)
Drill Bit
4mm X 38mm
(#8 X 1 1/2”)
Phillips Head
Install the SAO dispenser with the
cartridge 122cm (48”) from the
bottom of the dispenser to the floor.
Choose a location where both the
dispensing box and cartridge tube
will be affixed directly over a sink
or a floor drain.
Pressure Regulator
COLD WATER IN
to cartridge
(attach to cold water supply)
QUICK
DISCONNECTS
COLD WATER IN
hose
(121.92cm/
48”
)
Screen
Filter