Frequency Shift Keying (FSK)
Frequency shift keying (FSK) and RS485 operate in ASCII mode and share a common
address. The message formats for both FSK and RS485 are the same. Receiver link
specifications are provided in
.
FSK data is transmitted at 9600 baud with 8 data bits, no parity, no flow control, and
one stop bit.
Synchronization is maintained by the following method:
1. Once a
<
character is received, the link will be in sync. A state machine passes the
ASCII characters
The Rx 1+1 system is capable of responding to messages at a rate of one every
20 ms.
2. If the Rx 1+1 system does not respond within the maximum response time, the
command should be cyclically repeated.
Ethernet
Using Ethernet, you can communicate with the Rx 1+1 system through Telnet
(ASCII), the on-board Web server (HTTP), or through SNMP. The Rx 1+1 system
uses a static IP addressing structure and does not support DHCP. The Rx 1+1 system
is factory-configured as follows:
IP Address
192.168.1.254
IP Gateway
192.168.1.1
Subnet Mask
255.255.255.0
Telnet Port
23
Note:
Your computer should have a static IP address on the same subnet as the Rx 1+1
interface module. Using a suitable cable, connect the computer to the J1 connector on
the interface module.
Note:
An Ethernet hub will function with a straight connect cable. If an Ethernet hub is not
used to connect to the interface module, a crossover cable must be used instead.
Table 5.2
Receiver Link Specifications
Locking Range
±32.5 KHz
Input Impedance
50
Ω
Input Sensitivity
-15 dBm
Summary of Contents for Rx 1+1
Page 1: ...Receive Redundant Systems Operations Manual 24 Hour Technical Support 1 408 782 2166 ...
Page 6: ...iv ...
Page 10: ...viii This page intentionally left blank for double sided printing ...
Page 12: ...x This page intentionally left blank for double sided printing ...
Page 20: ...1 6 Introduction This page intentionally left blank for double sided printing ...
Page 36: ...2 16 Functional Description This page intentionally left blank for double sided printing ...
Page 84: ...6 6 Troubleshooting This page intentionally left blank for double sided printing ...
Page 145: ...Screen Shots E 13 IDC Low Threshold Sets the lowest permitted level down to 100 Ma ...
Page 158: ...E 26 Web Pages This page intentionally left blank for double sided printing ...
Page 161: ...Reference Drawings F 3 Figure F 2 Fabrication Drawing FBD 20786 XXXX Rev A ...
Page 163: ...Reference Drawings F 5 Figure F 4 Top View of Rx 1 1 System Showing Connector Locations ...