General Requirements
|
3-15
Engineered to Endure
J2 – M&C Interface
The M&C interface is a 19
-
pin circular socket connector used to
enable remote monitoring and control of IBUC operating parameters. Pin assignments
are shown in
. If the M&C port of the IBUC is going to be used, the cable
should be a shielded multi-conductor cable. For more information about fabricating
your own cable, see the IP cable drawing in
. An optional pre
-
assembled
IP test cable is available from Terrasat.
Note: Pin F is the return to close the circuit for RS232.
Table 3.4
Pin Assignments for M&C Interface Connector J2
Pin
Function
A
RESERVED
B
RESERVED
C
+5V
D
RS232 RXD
E
RS232 TxD
F
GROUND
G
RESERVED
H
RESERVED
J
Factory Reset
K
RESERVED
L
IBUC Alarm Output Normally Open
M
IBUC Alarm Output Common
N
Mute
P
IBUC Alarm Output Normally Closed
R
RESERVED
S
RESERVED
T
RESERVED
U
RESERVED
V
RESERVED