CM1
Description: Displays or sets the minor alarm mask of the unit. This is a hexadecimal
value. See
for available hexadecimal values..
Parameter:
<Hex Mask>
Minor alarm mask [Hexadecimal value.
below refers to configurable alarm mask values. Only the alarms shown
in the table are maskable out of all alarms available.
Table C.3
Configurable Alarm Mask
Transmit Alarm Mask
0x0008
Tx Output Threshold High Alarm
0x0010
Tx Output Threshold Low Alarm
0x0020
Tx Input Threshold High Alarm
0x0040
Tx Input Threshold Low Alarm
0x0080
High Temperature Alarm
Q
Query: CM1
Response: CM1=<Hex Mask>
C
Command: CM1=<Hex Mask>
Example: CM1=0x0008 will set the Tx Output Threshold High Alarm to
minor.
Response: CM1=<Hex Mask>
Summary of Contents for IBUC 2