Engineered to Endure
•
Continuous
In continuous mode, the input signal continues without interruption.
• Burst Timeout
Sets the longest allowable time between valid data bursts before the IBUC reports
an alarm. This command applies when the IBUC is set to burst power monitoring.
The set value must be between 0 and 300 seconds. 0 is the default value (No
Timeout).
• Burst Threshold
Sets the burst threshold for the IBUC. This value determines the level at which a
burst is considered valid. The threshold is for the output power level; the threshold
for input power is configured internally.
The value must be between rated power and no less than 2 dB below rated power.
Default values are listed in
.
• Gain Mode
Options include:
•
Open: no feedback in the measuring loop.
Keep in mind the open-loop gain is affected by temperature and frequency;
however, the temperature compensation feature is still active when the unit
operates with open-loop gain. Open is the default setting.
•
Automatic Gain Control (AGC)
•
Automatic Level Control (ALC)
Note:
The user should
not switch directly
from AGC/ALC to ALC/ACG. This action
may cause errors. Instead the user should first change from AGC/ALC to Open
Loop gain and then change to ALC/AGC. After Switch from the ALC/AGC Gain
Mode to Open Loop Mode, the user
must reset the Gain Control.
Table B.2
Default Values for Burst Threshold
Power Level
Default Value
Power Level
Default Value
004
16.0
050
27.0
005
17.0
060
28.0
008
19.0
080
29.0
010
20.0
100
30.0
012
21.0
125
31.0
016
22.0
150
32.0
020
23.0
175
32.4
025
24.0
200
33.0
030
25.0
300
35.0
040
26.0
400
36.0
Summary of Contents for IBUC 2
Page 6: ...iv Engineered to Endure Appendix F Glossary Glossary of Terms F 1 ...
Page 8: ...vi Engineered to Endure ...
Page 12: ...4 Engineered to Endure ...
Page 46: ...System Components 2 26 Engineered to Endure Figure 2 10 DC Power IBUC System Configuration ...
Page 57: ...General Requirements 3 9 Engineered to Endure Figure 3 2 IBUC 2 Field Installation ...
Page 196: ...I n d e x 4 ...