Terra UA410 Quick Start Manual Download Page 2

Installation instructions

1. Read the safety instructions first.

2. Mount the amplifier on the DIN rail or on the wall following the mounting instructions listed below.

3. Connections of the cables must be made according to the diagram in Figure 2. There are two ways for power supply 

connection: 12 V DC voltage can be supplied through DC input terminal or units of the system can be joined together using 

power distribution bus while only one of them connected to 12 V power supply unit. 

4. Power supply can be connected only when all connections are finished.

Operating

Input mode can be selected using input mode switch (3). One or two inputs modes are available. The one input mode 

offers input test feature, while the two inputs mode enables to summarize and amplify signals from both: RF input and auxilary 

input. The amplifier offers wide range of attenuation. Attenuation interstage switch (1) allows to provide output signal level 

attenuated by 10 dB. Fine tunning of the output level can be achieved using attenuation rotary switch (2), which broadens 

attenuation range up to 15 dB with 1 dB steps adjustment.

Installation example

s: 

Connection of cables

Mounting on DIN rail

Figure 4. Mounting to DIN rail

Figure 5. Mounting from DIN rail

 

Perpendicular to the wall 

Parallel to the wall 

Figure 3. Mounting of amplifier

Figure 2. Installation example 2

UA410

Mounting

Mounting on a wall by screws 

Mounting on a bracket (supplied)

Figure 1. Installation example 1