Terra tdx410C Manual Download Page 5

5

Device information table

This shows the data of module:

“Device model”: model of the module.

“Serial number”: serial number of the module.

“Software version”: module software version number.  

“Hardware version”: module hardware version number.    

“IP”: IP address of the control interface.

“System time”:  current time, synchronized from the TDT table of the input stream. Local time offset can be selected in 

the "IP settings" tab, see section 

7.4

.

“Up time”: time passed from last power-up or restart of the module. 

In the "Common status" table the following parameters are displayed at real time: input bit rate in kbps, output bit rate in 

kbps, processor load in percents, internal temperature in degrees of Celsius, power voltage in Volts.

In the "Diagnostic information" table all module errors and comments how to eliminate these errors are displayed.

Figure 8. Diagnostic information table with errors

7.3 RF input/output settings

This screen consists of six tables: "RF input", “RF output”, "List of services", "Input status", “RF output status”, “Description 

of other streams in the network”. The "RF input" table is used to configure parameters corresponding to the input satellite 

transponder (tdx410C module), terrestrial or cable transponder (ttx410C module). In the "List of services" table the list of 

services, available in the input transponder is displayed.  In the "Input status" table you can see real time status of the input 

section. In the "RF output status" table you can see real time status of the output section.

The "RF input" table is different according to the input signal of module.

7.3.1. RF input table

Figure 9. The "RF input" table of the tdx410C module

The „RF input" table (Figure 9) for tdx410C module consists of the following parameters:

"LNB LO frequency" - the LNB local oscillator lower frequency in megahertz. Use 9750 MHz for the universal converter.  

"LNB HI frequency" - the LNB local oscillator upper frequency in megahertz. Use 10600 MHz for the universal converter.  

 “LNB voltage” – power supply of the converter – can be set to “Off”, “Auto”, “13V”, “18V”, “13V/22kHz”, “18V/22kHz”. If 

“Auto” is selected, power supply voltage of the converter is chosen according to set the polarization  – 18V Horizontal, 13V 

Vertical; if the “Frequency” of the satellite exceeds the value F=(950+LNB Hi+2150+LNB Lo)/2, the 22 kHz signal is switched 

ON and “LNB Hi freq.” is selected. 

For example: LNB Hi=10,600, LNB Lo=9750, then F=(950+10,600+2150+9750)/2=11,725 MHz. When power supply of 

the converter is set to value different from "Auto."  to "LNB HI frequency", “Satellite” and "Polarization“ rows are disabled 

and the "LNB LO frequency" value is used for IF frequency calculation.    

“Satellite” – DISEQC command is used to select the satellite when the switch that supports DISEQC protocol is present. 

Possible commands:  “None”, “SAT A”, “SAT B”, “SAT C”, “SAT D”.

"Polarization" - the polarization of converter. Can be "Horizontal" or "Vertical".

 “Frequency” – the frequency of the satellite transponder in megahertz.  

 “Symbol rate” – the symbol rate of the satellite transponder in kilo symbols per second.

Summary of Contents for tdx410C

Page 1: ...ion table NIT Network information table and SDT Service description table table regeneration 3 Safety instructions Installation of the module must be done according IEC60728 11 and national safety standards Any repairs must be made by qualified personnel Do not expose this module to moisture or splashing water and make sure no objects filled with liquids such as vases are placed near or on the uni...

Page 2: ...ive the ACTIVITY 5 indicator blinks Perpendicular to the wall Parallel to the wall Figure 2 Mounting of the streamer 1 CA module slot PCMCIA socket 2 RF input of SAT IF signal DC output for LNB tdx410C RF input of terrestrial cable signal DC output for preamplifier ttx410C F socket 3 RF output input signal loop through F socket 4 ETHERNET control Ethernet interface RJ45 socket 5 ACTIVITY yellow in...

Page 3: ...3 Mounting on DIN rail Figure 5 Mounting or removing to from DIN rail of plastic spacers supplied Figure 3 Mounting to DIN rail Figure 4 Mounting from DIN rail 1 2 ...

Page 4: ...name and password The default user name and password is admin Enter the user name and password and click on Login button Note the default password admin can and must be changed as explained in the section 7 7 5 During initial configuration you need to change the default control interface TCP IP configuration as explained in the section 7 4 Control interface IP address reset to default procedure pr...

Page 5: ...ction In the RF output status table you can see real time status of the output section The RF input table is different according to the input signal of module 7 3 1 RF input table Figure 9 The RF input table of the tdx410C module The RF input table Figure 9 for tdx410C module consists of the following parameters LNB LO frequency the LNB local oscillator lower frequency in megahertz Use 9750 MHz fo...

Page 6: ...nal Unlocked the module has not synchronized with the input signal Input level RF signal level at the module input Level indication approximate The values of the following parameters are displayed only if the module has synchronized with the input signal Modulation standard detected standard of the input signal Possible values of the standard DVB S DVB S2 tdx410C DVB T DVB T2 DVB C ttx410C Frequen...

Page 7: ...module can be selected and descrambling status observed In the Enable column services for output TS are selected Column CC errors shows incoming TS CC error continuity count error status Figure 13 The List of services table The service type icon meanings SD TV service HD TV service radio service Click on the Watch button to see selected channel The module will start an UDP unicast streaming via th...

Page 8: ...s are not regenerated so even if service is descrambled some TV s might show service scrambled message because CA descriptors are left at PMT table 7 3 5 Output settings RF output On Off turns on off RF output Constellation modulation scheme of the output signal Possible values of the modulation scheme QPSK QAM16 QAM64 Code Rate FEC There are five valid coding rates 1 2 2 3 3 4 5 6 and 7 8 Guard i...

Page 9: ...ptured automatically by adding its IP address and pressing Load button In case if the frequency was added manually already that record will be updated Otherwise a new record will be inserted 7 4 IP settings This screen Figure 19 consists of three tables Control interface IP parameters Time parameters and IP status The IP parameters tables are used to configure Ethernet connection parameters In the...

Page 10: ...e description of the SNMP configuration table rows Read Community community name acts as a password that is shared by multiple SNMP agents and one or more SNMP managers The Read Community password is used for read only access to the modules parameters Write Community is the password used for read write access to the modules parameters Enable TRAP SNMP traps are alerts generated by agents on a mana...

Page 11: ... and the values of these parameter are corrected Local time offset in the log is used from the time parameters table see Figure 19 You can filter required messages setting corresponding Logs filtering checkboxes 7 7 2 Export parameters All of the data established on the module can be saved onto a backup file Inversely the configuration data saved on an appropriate file can be restored on the modul...

Page 12: ...at new password field The change of password will not take effect until you press the Modify button In the User management table you can manage users who will be able to login into the module Enter the new username and password in the appropriate fields select desired role for user and press the Add button to add new user or Update button to change settings of the user User role Admin enables the ...

Page 13: ...eters PCR restamping up to 5 PID s services Management port standard IEE802 3 10 100 Base T Supply voltage 12 V 1 V Current consumption 400 mA 450 mA Operating temperature range 0o 50o C Dimensions Weight packed 36x198x112 mm 0 78 kg Technical specifications pr pr pr pr pr pr pr pr pr pr pr pr pr software control without external DC feeding and CAM with CAM 0 6 A absolut max with CAM and external ...

Page 14: ...3 2 safety norm EN60065 RoHS norm EN50581 TERRA confirms that this product is in accordance with Custom Union Technical Regulations Electromagnetic compatibility of technical equipment CU TR 020 2011 On safety of low voltage equipment CU TR 004 2011 TERRA confirms that this product is in accordance with safety standard AS NZS 60065 and EMC standards of Australia Draugystes str 22 LT 51256 Kaunas L...

Reviews: