![Terra SRM940 Manual Download Page 4](http://html1.mh-extra.com/html/terra/srm940/srm940_manual_1089636004.webp)
Marking: v.0
Marking: v.1
User
Band
(UB)
PIN
Code
Bandwidth,
MHz
Central frequency,
MHz
Bandwidth,
MHz
Central frequency,
MHz
EN50494 EN50607
EN50494 EN50607
UB0
UB1
1
40
1210
1210
40
1210
no
UB2
2
40
1420
1420
40
1420
no
UB3
3
40
1680
1680
40
1680
no
UB4
4
40
2040
2040
40
2040
no
UB5
5
40
1284
1284
40
no
985
UB6
6
40
1516
1516
40
no
1050
UB7
7
40
1632
1632
40
no
1115
UB8
8
40
1748
1748
40
no
1275
UB9
9
40
no
970
40
no
1340
UB10
10
40
no
1010
40
no
1485
UB11
11
40
no
1050
40
no
1550
UB12
12
40
no
1090
40
no
1615
UB13
13
40
no
1130
40
no
1745
UB14
14
40
no
1170
40
no
1810
UB15
15
40
no
1330
40
no
1875
UB16
16
40
no
1370
40
no
1940
Marking: v.2
Bandwidth,
MHz
Central frequency,
MHz
EN50494 EN50607
46
1210
1210
46
1420
1420
46
1680
1680
46
2040
2040
46
1006
1006
46
1057
1057
46
1108
1108
46
1159
1159
46
no
1261
46
no
1312
46
no
1363
46
no
1471
46
no
1522
46
no
1573
46
no
1624
46
no
1731
Table 1
4
C
onfiguration
The default setting of the device can be changed using dedicated programmer and software
This multiswitch can be configured:
1. Up to 32 User Bands (UB) per pair outputs (total 64 UB) for use with STBs supporting DiSEqC commands according
to standard EN50607 (dSCR).
2. Default settings
Dynamic mode
can be changed to
Static mode
.
3. Default setting Satellites A/B/C/D can be changed to Satellites A/B (for installation 2 Quattro LNBs (SAT A/B in the
case Quattro LNB IF range input mode).
PC Windows software can be free downloaded from
www.terraelectronics.com
.
Output configuration must be the same per pair of outputs, but can be different in others pairs. Each pair of outputs is
configured separately. Pay attention to the numbering of outputs.
See programmer user manual for more information.
Recommended accessories
1. Power supply PS202F
2. dSCR power inserter PI012
3. Multiswitch programmer PC102W
This product complies with the relevant clauses of the European Directive 2002/96/EC. The unit must be recycled or discarded according to applicable local
and national regulations.
Equipment intended for indoor usage only.
Functional grounding. Connect to the main potential equalization.
This product is in accordance to following norms of EU: EMC norm EN50083-2, safety norm EN IEC62368-1, RoHS norm EN50581.
This product is in accordance with Custom Union Technical Regulations: “Electromagnetic compatibility of technical equipment“ CU TR 020/2011,
“On safety of low-voltage equipment“ CU TR 004/2011.
This product is in accordance with safety standard AS/NZS 60065 and EMC standards of Australia.