DC voltages diagnostic LEDs meanings described in Table 2.

Table 2

.

LED “V”  LED “H” Voltage at 

DC IN

DC from V 

lines switch

DC to / 

from H lines 

switch

Voltage 

in V line

Voltage 

in H line

Warnings 

and notes

blank

Yellow

15…20 V

OFF

OFF

0 V

0 V

Normal operation. 

Multiswitch powered from 

DC IN port.

blank

Green

0 V 

OFF

ON

0 V

15…20 V Normal operation. 

Multiswitch powered from 

H line.

blank

Blinking 

Yellow

 / 

Green

1.  15…20 V

2.  15…20 V

OFF

OFF

ON

OFF

0 V

0 V

15…20 V

15…20 V

Normal operation. 

Multiswitch powered from 

DC IN port and power 

pass from DC IN to H 

lines

Normal operation. 

Multiswitch powered from 

DC IN port. Voltage in H 

line from another system 

power point.

blank

Red

1. < 14 V

2.  0 V

OFF

OFF

OFF

ON

0 V

0 V

0 V

<  14 V

Low voltage at DC IN

.

Multiswitch powered from 

DC IN port.

Attention! increased 

current consumption

.

Low voltage in H line

Multiswitch powered 

from H line. Voltage in H 

line from another system 

power point.

Attention! increased 

current consumption

.

Green

blank

0 V

ON

OFF

15…20 V 0 V

Normal operation. 

Multiswitch powered from 

V line.

Red

blank

0 V

ON

OFF

<  14 V

0 V

Low voltage in V line

Multiswitch powered 

from V line. Voltage in V 

line from another system 

power point.

Attention! increased 

current consumption

.

Green

Yellow

15…20 V

OFF

OFF

15...20 V 0 V

Normal operation.

Multiswitch powered from 

DC IN port. Voltage in V 

line from another system 

power point.

Green

Green

0 V

One of switches is ON

15...20 V 15...20 V

Normal operation. 

Multiswitch powered from 

V or H line (depending on 

which switch is ON).

7

Summary of Contents for SRM524

Page 1: ...524 SRM544 signals negating the need for any gain or level adjustments in most installations Multiswitch is built into a zinc alloy die cast housing for extreme interference immunity The housing of multiswitches meets more stringent screening requirements according to EN50083 2 class A Control according to EN50494 EN50607 SCR dSCR commands as well as Legacy 13 V 18 V 22 kHz commands According to t...

Page 2: ...stem Floating voltages can be created in an un earthed system which may cause damage and can be dangerous Momentary short circuit of any cables may be enough to damage the sensitive electronics within the multiswitch or the connected system Always allow plenty of ventilation around the multiswitch and do not allow it to be covered with materials such as loft insulation We recommend at least 5 cm o...

Page 3: ...o from H lines Voltage in trunk Power via DC IN Low voltage in trunk dSCR Legacy DTT Manual 1 2 3 4 5 1 2 3 4 5 16 11 12 22 6 7 8 9 10 21 18 15 17 19 20 LNB Off DTT Frequency SAT TV range DTT Trunk loss SAT TV DTT Current consumption 20V 500 mA max 290 2350 MHz 47 862 MHz 4 dB 4 dB dSCR multiswitch SRM544 H H V DTT H H V V V DC IN 20V 2A dSCR Legacy DTT 2 1 Pair A Pair B 2 1 DC to from On Wideband...

Page 4: ...air A UB DTT 13 dSCR output2 pair B UB DTT SRM544 SRM544T only 14 dSCR output1 pair B UB DTT SRM544 SRM544T only 15 Wideband Quattro switch 16 DC IN 20 V power input switchable to H lines by switch pos 17 see Installation instructions 17 DC power to from H trunk lines switch see Installation instructions 18 DC power from V trunk lines switch see Installation instructions 19 DC IN and DC in H trunk...

Page 5: ...ths 5 Figure 3 Diagram of DC paths LNB Off DTT H H V DTT H H V V V DC IN 20V 2A DC to from On Wideband Quattro On Off DC from DiSEqC control V SAT A SAT B SAT A SAT B H V lines H lines Voltage in trunk DC DC converter ...

Page 6: ... H lines if it can accept 20V SERIOUS DAMAGE OF IT CAN OCCUR 3 Multiswitch is powered from H trunk lines building new SCR dSCR system 18 V 20 V upgrading systems 15 V 18 V ON OFF WARNING Don t exceed the current capability of system power supply and H trunk lines See Technical characteristics SERIOUS DAMAGE CAN OCCUR IF OVERLOADED 4 Multiswitch is powered from V trunk lines building new SCR dSCR s...

Page 7: ...ower point blank Red 1 14V 2 0V OFF OFF OFF ON 0V 0V 0V 14V Low voltage at DC IN Multiswitch powered from DC IN port Attention increased current consumption Low voltage in H line Multiswitch powered from H line Voltage in H line from another system power point Attention increased current consumption Green blank 0V ON OFF 15 20V 0V Normal operation Multiswitch powered from V line Red blank 0V ON OF...

Page 8: ...switches set see Figure 1 pos 17 18 in position OFF Table 3 Marking v 0 Marking v 1 Marking v 2 User Band UB PIN Code Bandwidth MHz Central frequency MHz Bandwidth MHz Central frequency MHz Bandwidth MHz Central frequency MHz EN50494 EN50607 EN50494 EN50607 EN50494 EN50607 UB0 46 1210 1210 UB1 1 40 1210 1210 40 1210 1210 46 1420 1420 UB2 2 40 1420 1420 40 1420 1420 46 1680 1680 UB3 3 40 1680 1680 ...

Page 9: ...otal 32 UB SRM544 SRM544T total 64 UB for use with STBs supporting DiSEqC commands according to standard EN50607 dSCR 2 Default settings Dynamic mode can be changed to Static mode 3 Default setting Satellite A B can be changed to C D see Application diagrams for installation 4 wideband LNBs SAT B C D in the case Quattro LNB IF range input mode PC Windows software can be free downloaded from www te...

Page 10: ...mode 32 max per pair outputs configurable with combined DTT user band bandwidth 20 60 MHz adjustable dSCR mode dSCR mode output level 84 dBµV adjustable AGC controlled legacy mode output level 78 dBµV AGC controlled typical DTT output level 82 dBµV max 8 DTT channels AGC controlled adjustable DTT loss 18 dB Decoupling SAT IF inputs SAT IF inputs 30 dB SAT IF inputs tap outputs 30 dB SAT IF Terr TV...

Reviews: