dSCR (Digital satellite cable router) multiswitches SRM524, SRM544, SRM524T, SRM544T

Vers. 1.01

1

Product description

Cascadable single cable wideband multiswitches SRM524, SRM544 and SRM524T, SRM544T are intended for the 

distribution of satellite and terrestrial signals for up to 32 satellite tuners or receivers on each outputs pair.

The multiswitches have 4 passive Wideband SAT IF (for connecting 2 Wideband LNBs) and 1 passive Digital Terrestrial 

TV (DTT) trunk lines.

The multiswitches have 1 DC input port and dedicated control/configuration port (see Figure 1 and chapter „Installation 

instructions”).

The multiswitches may be simply switched to Quattro SAT IF range input mode by dedicated switch.

SRM524

SRM524T

 is are cascadable single cable multiswitches with 1 pair subscribers outputs (2 outputs total).

SRM544

SRM544T

 is are cascadable single cable multiswitches with 2 pairs subscribers outputs (4 outputs total).

SRM524

 and 

SRM544

 have active Automatic gain control (AGC) Digital terrestrial television (DTT) path to subscribers 

outputs (see Table „Technical characteristics”).

SRM524T

 and 

SRM544T

 have passive DTT path to subscribers outputs (see Table „Technical characteristics”).

The multiswitches are intended for the distribution of satellite and DTT signals for up to 32 satellite tuners or receivers on 

each outputs pair and have 5 x DC power modes for convenient DC powering options (see chapter „Installation instructions”).

The devices ensures an independent access for every subscriber to any SAT IF and DTT trunk line.
These multiswitches automatically detect Legacy/SCR/dSCR commands from the receiver. The dSCR switches also 

feature fully automatic level control for SAT IF and DTT (SRM524, SRM544) signals, negating the need for any gain or level 
adjustments in most installations. 

Multiswitch is built into a zinc alloy die cast housing for extreme interference immunity. The housing of multiswitches meets 

more stringent screening requirements according to EN50083-2, class A.

Control according to EN50494/EN50607 (SCR/dSCR) commands as well as Legacy (+13 V/+18 V/22 kHz) commands.

According to the standard ETSI EN 303 354 V.1.1.1, TERR TV band amplifier of multiswitch type is Launch, selectivity 

clasification 0.

Safety instructions

Installation of the multiswitches must be done according IEC60728-11 and national safety standards. 
The multiswitches are powered from the stabilized power 20 V. This voltage is not dangerous to life. 
External power supply must have a short circuit protection.
Any repairs must be made by skilled personnel. 
To avoid damaging of the multiswitches do not connect the supply voltage until all cables have been connected correctly. 

The device shall be mounted in vertical position with RF input connectors on the top side on a wall or other nonflamable 

surface.

The multiswitches must be fixed with steel screws Ø 4-4.5 mm. The screws are not included in a package.
Do not expose multiswitches to moisture or splashing water and make sure no objects filled with liquids, such as vases, 

are placed near or on the unit. 

Avoid placing the multiswitches  next to central heating components or direct sunlight and in areas of high humidity. 

No naked flame sources, such as lighted candles, should be placed on multiswitch. 

If the multiswitches have been kept in cold conditions for a long time, keep it in warm room no less than 2 hours before 

powering. 

The ventilation should not be impeded by covering the multiswitches with items, such as newspapers, table-cloths, curtains. 
The mains socket of external power supply must be easily accessible.

Manual in .pdf 

Summary of Contents for SRM524

Page 1: ...524 SRM544 signals negating the need for any gain or level adjustments in most installations Multiswitch is built into a zinc alloy die cast housing for extreme interference immunity The housing of multiswitches meets more stringent screening requirements according to EN50083 2 class A Control according to EN50494 EN50607 SCR dSCR commands as well as Legacy 13 V 18 V 22 kHz commands According to t...

Page 2: ...stem Floating voltages can be created in an un earthed system which may cause damage and can be dangerous Momentary short circuit of any cables may be enough to damage the sensitive electronics within the multiswitch or the connected system Always allow plenty of ventilation around the multiswitch and do not allow it to be covered with materials such as loft insulation We recommend at least 5 cm o...

Page 3: ...o from H lines Voltage in trunk Power via DC IN Low voltage in trunk dSCR Legacy DTT Manual 1 2 3 4 5 1 2 3 4 5 16 11 12 22 6 7 8 9 10 21 18 15 17 19 20 LNB Off DTT Frequency SAT TV range DTT Trunk loss SAT TV DTT Current consumption 20V 500 mA max 290 2350 MHz 47 862 MHz 4 dB 4 dB dSCR multiswitch SRM544 H H V DTT H H V V V DC IN 20V 2A dSCR Legacy DTT 2 1 Pair A Pair B 2 1 DC to from On Wideband...

Page 4: ...air A UB DTT 13 dSCR output2 pair B UB DTT SRM544 SRM544T only 14 dSCR output1 pair B UB DTT SRM544 SRM544T only 15 Wideband Quattro switch 16 DC IN 20 V power input switchable to H lines by switch pos 17 see Installation instructions 17 DC power to from H trunk lines switch see Installation instructions 18 DC power from V trunk lines switch see Installation instructions 19 DC IN and DC in H trunk...

Page 5: ...ths 5 Figure 3 Diagram of DC paths LNB Off DTT H H V DTT H H V V V DC IN 20V 2A DC to from On Wideband Quattro On Off DC from DiSEqC control V SAT A SAT B SAT A SAT B H V lines H lines Voltage in trunk DC DC converter ...

Page 6: ... H lines if it can accept 20V SERIOUS DAMAGE OF IT CAN OCCUR 3 Multiswitch is powered from H trunk lines building new SCR dSCR system 18 V 20 V upgrading systems 15 V 18 V ON OFF WARNING Don t exceed the current capability of system power supply and H trunk lines See Technical characteristics SERIOUS DAMAGE CAN OCCUR IF OVERLOADED 4 Multiswitch is powered from V trunk lines building new SCR dSCR s...

Page 7: ...ower point blank Red 1 14V 2 0V OFF OFF OFF ON 0V 0V 0V 14V Low voltage at DC IN Multiswitch powered from DC IN port Attention increased current consumption Low voltage in H line Multiswitch powered from H line Voltage in H line from another system power point Attention increased current consumption Green blank 0V ON OFF 15 20V 0V Normal operation Multiswitch powered from V line Red blank 0V ON OF...

Page 8: ...switches set see Figure 1 pos 17 18 in position OFF Table 3 Marking v 0 Marking v 1 Marking v 2 User Band UB PIN Code Bandwidth MHz Central frequency MHz Bandwidth MHz Central frequency MHz Bandwidth MHz Central frequency MHz EN50494 EN50607 EN50494 EN50607 EN50494 EN50607 UB0 46 1210 1210 UB1 1 40 1210 1210 40 1210 1210 46 1420 1420 UB2 2 40 1420 1420 40 1420 1420 46 1680 1680 UB3 3 40 1680 1680 ...

Page 9: ...otal 32 UB SRM544 SRM544T total 64 UB for use with STBs supporting DiSEqC commands according to standard EN50607 dSCR 2 Default settings Dynamic mode can be changed to Static mode 3 Default setting Satellite A B can be changed to C D see Application diagrams for installation 4 wideband LNBs SAT B C D in the case Quattro LNB IF range input mode PC Windows software can be free downloaded from www te...

Page 10: ...mode 32 max per pair outputs configurable with combined DTT user band bandwidth 20 60 MHz adjustable dSCR mode dSCR mode output level 84 dBµV adjustable AGC controlled legacy mode output level 78 dBµV AGC controlled typical DTT output level 82 dBµV max 8 DTT channels AGC controlled adjustable DTT loss 18 dB Decoupling SAT IF inputs SAT IF inputs 30 dB SAT IF inputs tap outputs 30 dB SAT IF Terr TV...

Reviews: