2
Application diagrams
1
.
DC IN
-
connector 3.5 mm/1.3 mm
2
.
DC IN
10 V ÷ 20 V
, RF OUT
-
RF signal output connector (F socket)
3
. LED output level indicator
4
. Functional grounding clamp
5
. Common connector SC/APC
5a
- COM label
6
. BOSA connector SC/APC or SC/UPC
6a
- BOSA label
Power supply unit 10 V
÷
20 V DC:
3.5 mm/1.3 mm or 5.5 mm/2.1 mm;
Power supply is not supplied with receiver.
j
Reducer:
Socket 5.5 mm/2.1 mm, plug 3.5 mm/1.3 mm;
Reducer is supplied in scope
of the optical receiver delivery.
REQUIREMENTS FOR EXTERNAL POWER SUPPLY UNIT
• Output voltage
+10 V min ...+20 V max
• Output current
> 0.07 A
• Ripple at single and/or double mains frequency < 20 mV p-p
• Ripple & noise
< 180 mV p-p
• Output connector type
3.5/1.3 (+) plug or type 5.5/2.1 (+) plug
• Short circuit protection
• Double insulated (marked
)
• Meet EN 55022 class B conducted emisions requirements, measuring with grounded load
RF
TV
4
1
2
OPTICAL
Optical receiver OD007H
10-20V
70mA
DC IN
DC IN
RF OUT
high
OK
low
RF
signal
level
3
5
a
6a
COM
BOSA
5
6