Terra Universal Smart WhisperFlow Installation And Operation Manual Download Page 2

 

 

ECM

 

Fan/Filter Unit

       

Installation and Operation Manual    

Doc. 1788-14

 

© 

Copyright 2018 Terra Universal Inc.   

All rights reserved 

Revised November 2019 

 

 

Terra Universal, Inc.  •  TerraUniversal.com  •  800 S. Raymond Ave.  •  Fullerton, CA  92831  •  TEL: (714) 578-6000  •  FAX: (714) 578-6020 

2

 

 

6.0

 

EC Motor Control Card Set-up 

 

6.1  Overview 

 

The EC Motor Control Card is a variable-speed controller designed for brushless DC 

(BLDC), electrically-commutated (EC) motors.  The control card features industry 

standard MODBUS® networking, precision speed control (1-100%), and closed-loop 

control capability that supports a variety of sensors such as air pressure, air flow, and 

particle counts.  The EC Motor Control panel provides access to LED diagnostics, 

manual speed adjustment, test probe jacks, CAT5e ports, the Control Mode DIP Switch, 

and the MODBUS® Address DIP Switch Bank. 

 

 

 

 

EC Motor Control Card 

 

Operating Temperature: 0 – 40°C 

 

Open-frame PCB with standoffs; Panel-mounted 

 

12-24V DC Power Supply (or network power) 

 

Two non-directional CAT5e/RJ45 connections for networking 

 

Motor Tachometer RPM Control 

Analog Control Options 

 

5-10V from controlled voltage source 

 

4-20mA signal from a sensor or potentiometer 

 

Internal Closed-Loop Control 

 

Manual Speed Adjustment 

PWM Speed Command Signal 

 

10V, 80Hz 

TACH Motor Speed Input 

 

10V @ 1mA needed switched to ground 

 

Maximum 5000 RPM measured 

 

Minimum 60 RPM measured 

Industry Standard MODBUS® Networking 

 

RTU Protocol 

 

RS485 9600,8,n,1 

Summary of Contents for Smart WhisperFlow

Page 1: ...mutative motor driving a forward curved centrifugal impeller Air is drawn into the unit through a pleated pre filter and in turn to an insulated chamber where it is then directed to an exit HEPA filter with a built in diffuser The unit can also be equipped with a 3 8 diameter challenge port which can be used to take differential pressure measurements to monitor filter performance or insert aerosol...

Page 2: ...sure air flow and particle counts The EC Motor Control panel provides access to LED diagnostics manual speed adjustment test probe jacks CAT5e ports the Control Mode DIP Switch and the MODBUS Address DIP Switch Bank EC Motor Control Card Operating Temperature 0 40 C Open frame PCB with standoffs Panel mounted 12 24V DC Power Supply or network power Two non directional CAT5e RJ45 connections for ne...

Page 3: ... Bank S1 SWITCH 1 ON SWITCH 2 OFF Network Control Mode DIP Switch Bank S1 SWITCH 1 OFF SWITCH 2 ON Closed Loop Feedback Network Control Mode DIP Switch Bank S1 SWITCH 1 ON SWITCH 2 ON Example Addresses in Network Mode MODBUS Address Value 1 DIP Switch Bank S2 SWITCH 1 ON MODBUS Address Value 21 DIP Switch Bank S2 SWITCHES 1 3 5 ON NOTE Address zero should not be used as it is reserved for global c...

Page 4: ...Alone Operation Power Source Ratings Supply Transformer Voltage Rating 12 24V AC Supply Transformer Power Rating 2 VA Regulated DC Supply Voltage Rating 14 30V DC Regulated DC Supply Power Rating 2 W Extended Accessory Output Currents for Stated Input Voltage Condition Input Voltage Accessory Current DC mA2 Suggested AC DC Source Power Rating 5V 10V V RFU VA 14V DC Regulated 300 300 500 20 20 30 3...

Page 5: ...parately For Terra s Policy and Procedures for Returning Goods see Terra s Internet site www TerraUniversal com Generally customers can improve the chance of collecting on a freight claim by following these procedures 1 formally requesting that the carrier inspect the shipment immediately upon suspecting damage or shortage to verify condition 2 notifying the carrier upon discovery of concealed dam...