Maintenance 

 

 

Disconnect the unit from the power supply before servicing.

 

WARNING 

 

The IonBar™ requires little maintenance beyond occasional cleaning. Frequency of cleaning depends on the 

cleanliness of air in the immediate vicinity of the IonBar™. 

 

The emitter housing may be cleaned using alcohol or other mild detergent and de-ionized water. 

 

If deposits are observed on the emitter tips, 

 

1.

 

Disconnect the IonBar™ from system power. 

 

2.

 

Use a cleanroom swab moistened with a cleaning solution of 50% isopropyl alcohol and 50% de-ionized water to 

remove deposits from the emitter points. 

 

3.

 

If deposits cannot be removed, or if the tips appear worn or bent, the IonBar™ may not discharge surfaces with 

optimal efficiency. In this case, replace the tips. Use a pencil eraser or needle-nosed pliers to remove the old tip. 

Insert the new tip and gently press until it seats against the connector; no twisting is necessary. 

 

4.0

 

Specifications 

 

Replacement Parts 

Product 

Catalog # 

120VAC Power Transformer 

2005-09A 

220VAC Power Transformer 

2005-09A-220 

Replacement Titanium Emitters 

2005-45 

Low-Voltage Power Cable 

2005-27 

 

General IonBar™ Specifications 

Construction 

 

Exterior 

PVC 

Emitters 

Machined titanium; 3-year estimated life 

(Field replaceable) 

Emitter Output 

12,000V 

Power Ratings 

 

System Power 

24 VAC 

Input Power (Wall Transformer) 

120/220VAC, 50/60Hz 

Current Draw 

104 mA (44” model) 

Performance 

 

Static Decay Time 

Discharge times directly under the IonBar™ 

average 28 seconds (from ± 1,000 volts to 100 

volts), measured in a 4-foot laminar flow hood 

with air speed of 90 feet/minute. 

Summary of Contents for IonBar

Page 1: ...ide Document No 1800 45 IonBar Ionizing Bar Copyright 2016 Terra Universal Inc All rights reserved Revised November 2016 Terra Universal Inc TerraUniversal com 800 S Raymond Ave Fullerton CA 92831 TEL 714 578 6000 FAX 714 578 6020 ...

Page 2: ...ods Preinstalled IonBars can also be purchased individually and installed by the user in the desired application An installation kit with standard FFU mounting brackets is sold separately and includes the power supply transformer NOTE For installation in a hood the overall hood width should be at least 2 greater than the length of the desired IonBar Proprietary Notice This manual pertains to propr...

Page 3: ...e mounting brackets installed place the IonBar in the ceiling bay where the fan filter unit goes The mounting brackets will rest upon the frame of the ceiling bay no other fasteners are required Simply lower the FFU into the ceiling bay and allow the weight of the FFU to hold the IonBar in position Installation on Gloveboxes When ordered with a glovebox the IonBar will be mounted to a stainless st...

Page 4: ...r transformer If the IonBar is ordered with the Installation Kit the power transformer power cable and appropriate mounting clips will be included 1 Use a telephone type connector and low voltage cable to connect the IonBar to the power transformer 2 Connect the transformer to the appropriate power supply 120VAC or 240VAC NOTE A single transformer provides ample power for up to 20 emitter pairs De...

Page 5: ...emove deposits from the emitter points 3 If deposits cannot be removed or if the tips appear worn or bent the IonBar may not discharge surfaces with optimal efficiency In this case replace the tips Use a pencil eraser or needle nosed pliers to remove the old tip Insert the new tip and gently press until it seats against the connector no twisting is necessary 4 0 Specifications Replacement Parts Pr...

Page 6: ...0Hz Power Rating 1A List of Input Connections Telephone cable connector low voltage List of Output Connections Telephone cable connector wall transformer Equipment Installation Assembly See Section 2 Installation Page 3 Protective Earthing Grounding N A Utility Requirements None Equipment Operation Operating Controls None Disconnect Device Wall transformer see warning on Page 5 Accessory Connectio...

Page 7: ...separately For Terra s Policy and Procedures for Returning Goods see Terra s Internet site www TerraUniversal com Generally customers can improve the chance of collecting on a freight claim by following these procedures 1 formally requesting that the carrier inspect the shipment immediately upon suspecting damage or shortage to verify condition 2 notifying the carrier upon discovery of concealed d...

Reviews: