WARNING

 

READ THE FOLLOWING WARNINGS CAREFULLY 

 

 

If  your  application  involves  flammable  exhaust,  you  must  use  an  Explosion-Proof  Blower/Ventilator. 

Contact Terra for more information. 

 

 

If your hood is configured as an Exhaust Purification System, you must ensure that all toxic fumes have 

been  effectively  filtered  out  of  the  exhaust  before  releasing  it  back  into  the  work  environment.  Terra 

recommends use of a toxic gas detector to monitor these fumes. 

 

 

If your system functions as an exhaust ventilator but does not incorporate the purification filter, you can 

direct  hazardous  exhaust  from  the  ventilator  outlet  to  your  in-house  exhaust  system.  You  will  need  a 

Flange Adapter Panel for this (contact Terra for assistance). 

 

 

Make sure that your hood and filter housing are compatible with the fumes involved in your application!  

Acrylic hoods are not designed for corrosive or flammable fumes.  Static-Dissipative PVC hoods and filter 

housings are safe with a wide range of chemicals that damage acrylic. 

 

 

Activated  carbon  filters  operate  with  varying  efficiency  on  chemical  vapors  –  thorough  testing  for 

suitability is advised before operation. 

 

 

Air speed and filter integrity must be monitored and tested frequently.  

 

 

Terra Universal assumes no liability for damage or injury that may result as a consequence of improper 

filter selection, use or testing. 

 

 

NOTE

 

Terra Universal also offers toxic gas detection systems for testing the activated carbon filter for saturation.  

Please contact a Terra representative for more information or follow the link below: 

https://www.terrauniversal.com/safety-equipment/toxic-gas-detector-systems.php

  

 

 

Proprietary Notice

 

 

This  manual  pertains  to  proprietary  devices  manufactured  by  Terra 

Universal,  Inc.  Neither  this  document  nor  any  portion  of  it  may  be 

reproduced  in  any  way  without  prior  written  permission  from  Terra 

Universal.

 

Terra Universal makes no warranties applying to information contained 

in  this  manual  or  its  suitability  for  any  implied  or  inferred  purpose.  

Terra  Universal  shall  not  be  held  liable  for  any  errors  this  manual 

contains or for any damages that result from its use.

 

Safety Notice

 

 

A thorough familiarity with all operating guidelines is essential to safe 

operation of the product.  Failure to observe safety precautions could 

result in poor performance, damage to the system or other property, or 

serious bodily injury or death. 

 

The following symbols are intended to call your attention to two levels 

of hazard involved in operation: 

 

Cautions  are  used  when  failure  to  observe  instructions 
could result in significant damage to equipment. 

CAUTION 

 

 

Warnings  are  used  when  failure  to  observe  instructions 
or precautions could result in injury or death. 

WARNING 

The information presented here is subject to change without notice. 

Summary of Contents for Ductless Exhaust Fume Hood

Page 1: ... Document No 1800 72 Ductless Exhaust Fume Hood Copyright 2016 Terra Universal Inc All rights reserved Revised December 2016 Terra Universal Inc TerraUniversal com 800 S Raymond Ave Fullerton CA 92831 TEL 714 578 6000 FAX 714 578 6020 ...

Page 2: ... and filter integrity must be monitored and tested frequently Terra Universal assumes no liability for damage or injury that may result as a consequence of improper filter selection use or testing NOTE Terra Universal also offers toxic gas detection systems for testing the activated carbon filter for saturation Please contact a Terra representative for more information or follow the link below htt...

Page 3: ...tures a built in air Vaneometer Air Velocity Meter for easy monitoring of the exhaust air speed Terra s High Clearance Chemical Fume Hood Nos 2900 30 through 2900 33 provides over 28 of vertical clearance with the access shield open making it ideal for distillation and other operations with large glassware or equipment It is available in several hood materials and includes a spill tray made of whi...

Page 4: ...y two years depending on use As these filters clog you will notice a reduction in air speed and noisier blower operation To replace filters from inside the work area The filter s are held securely in place by two plated steel pawls along the front edge of the filter housing Rotate each black knob 90 to release the filter s and then carefully lower them out of the housing Insert the replacement fil...

Page 5: ... x 0 5 Weight 104 lbs Electrical 120 240VAC 50 60Hz 20A 1Ph Individual Blower Specifications Table Horsepower HP Power Use 196 W Max Amps 1 96 A Max Airflow 598 CFM Fan Speed 3104 RPM Fan Wheel Type Backward centrifugal Impeller High impact polypropylene external rotor Insulation Class B Enclosure IP44 Housing Heavy gauge galvanized sheet metal Motor Bearings Permanently sealed self lubricating ba...

Page 6: ...or separately For Terra s Policy and Procedures for Returning Goods see Terra s Internet site www TerraUniversal com Generally customers can improve the chance of collecting on a freight claim by following these procedures 1 formally requesting that the carrier inspect the shipment immediately upon suspecting damage or shortage to verify condition 2 notifying the carrier upon discovery of conceale...

Reviews: