Terra Universal Ductless Exhaust Fume Hood Installation And Operating Manual Download Page 1

 

 

 

Installation and Operating Guide   

Document No. 1800-72

 

Ductless Exhaust Fume Hood 

© 

Copyright 2016 Terra Universal Inc.  All rights reserved. 

• Revised December 2016 

Terra Universal, Inc.  •  TerraUniversal.com  •  800 S. Raymond Ave.  •  Fullerton, CA  92831  •  TEL: (714) 578-6000  •  FAX: (714) 578-6020

 

Summary of Contents for Ductless Exhaust Fume Hood

Page 1: ... Document No 1800 72 Ductless Exhaust Fume Hood Copyright 2016 Terra Universal Inc All rights reserved Revised December 2016 Terra Universal Inc TerraUniversal com 800 S Raymond Ave Fullerton CA 92831 TEL 714 578 6000 FAX 714 578 6020 ...

Page 2: ... and filter integrity must be monitored and tested frequently Terra Universal assumes no liability for damage or injury that may result as a consequence of improper filter selection use or testing NOTE Terra Universal also offers toxic gas detection systems for testing the activated carbon filter for saturation Please contact a Terra representative for more information or follow the link below htt...

Page 3: ...tures a built in air Vaneometer Air Velocity Meter for easy monitoring of the exhaust air speed Terra s High Clearance Chemical Fume Hood Nos 2900 30 through 2900 33 provides over 28 of vertical clearance with the access shield open making it ideal for distillation and other operations with large glassware or equipment It is available in several hood materials and includes a spill tray made of whi...

Page 4: ...y two years depending on use As these filters clog you will notice a reduction in air speed and noisier blower operation To replace filters from inside the work area The filter s are held securely in place by two plated steel pawls along the front edge of the filter housing Rotate each black knob 90 to release the filter s and then carefully lower them out of the housing Insert the replacement fil...

Page 5: ... x 0 5 Weight 104 lbs Electrical 120 240VAC 50 60Hz 20A 1Ph Individual Blower Specifications Table Horsepower HP Power Use 196 W Max Amps 1 96 A Max Airflow 598 CFM Fan Speed 3104 RPM Fan Wheel Type Backward centrifugal Impeller High impact polypropylene external rotor Insulation Class B Enclosure IP44 Housing Heavy gauge galvanized sheet metal Motor Bearings Permanently sealed self lubricating ba...

Page 6: ...or separately For Terra s Policy and Procedures for Returning Goods see Terra s Internet site www TerraUniversal com Generally customers can improve the chance of collecting on a freight claim by following these procedures 1 formally requesting that the carrier inspect the shipment immediately upon suspecting damage or shortage to verify condition 2 notifying the carrier upon discovery of conceale...