Optical amplifier settings table

“Operation mode”: switch amplifier to Automatic Power Control (APC) mode or turn amplifier off.

WARNING: this device is 

laser 3R

 class product. You must take all safety precautions as described in section 

“4. Safety of laser product” when switching optical amplifier to active APC mode

.

“Shutdown if low optical input”: shutdown amplifier laser diode if optical input level is below “Low optical input level” 

threshold value.

“Low optical input level”: low optical input threshold value in dBm.

“Alarm temperature”: module inside temperature above which module will display a warning.

“Shutdown temperature”: module inside temperature above which module will turn laser diode off.

Press “Update” to change amplifier settings and wait until saving process is finished.

Figure 8. Amplifier configuration screen

9.4 IP Settings

This menu section consists of two tables related to network and time settings. The “IP settings” table is used to configure 

the device Ethernet connection. “Date, Time” table allows you to configure system time settings.

IP settings table

"MAC Address": the physical address of the module Ethernet network card is displayed automatically.

"IP Address": enter the IP address that you wish to assign to the module. This address must fall within the range of local 

network addresses.

"Subnet mask": enter the local network mask.

"Gateway": enter the IP address of the gateway. This information is required only if you want to access the module from 

outside of your local network, send the SNMP traps or use NTP client. 

“DNS server”: enter the IP address of the DNS server.

Press “Update” button to change device IP settings.

Figure 9. IP settings screen

Date and Time settings table

“System time”: current system time and date.

“Time zone”: local time zone. Choose value according to your location.

“Date and time source”: choose automatic date and time synchronize with NTP server or manual date and time setup.

“NTP server”: NTP server address or hostname which is used to update system time. This parameter is unavailable if 

“Manual setup” option is selected.

“Date”: manually insert time in this field. This field is unavailable if “NTP server” option is selected.

“Time”: manually insert date in this field. This field is unavailable if “NTP server” option is selected.

Press “Update” button to change time and date settings.

Summary of Contents for OAD518

Page 1: ...t be made by a qualified personnel Do not connect the 12 V power supply unit into the mains socket until all cables of amplifier have been correctly connected The mains socket must be easily accessible Disconnect the amplifier power supply by removing the power supply cable from the mains socket Do not expose this device to moisture or water splashes make sure no liquid filled objects e g vases ar...

Page 2: ...vice Never leave equipment with radiating bare fibers accessible always cap the connectors 5 Cleaning of optical connectors The fiber ends may be damaged if contaminated connectors are inserted The warranty does not cover some types of damage made by the customer The standard optical connector for optical amplifier is FC APC During the operation each fiber connector may be contaminated by dust or ...

Page 3: ...ed 18 amplifier optical input FC APC socket 19 functional grounding clamp 7 Installation instructions Read the safety instruction first All settings can be changed using Web browser and Ethernet interface Disconnect the power supply unit from the mains before making any fiber optic cables connections Mount the module on DIN RAIL or individual holder Connect all necessary fiber optic powering and c...

Page 4: ...IN rail 8 MOUNTING The module or mounting bracket must be fixed with steel screws Ø 3 5 4 mm The screws are not included in a package Mounting on a wall by screws Mounting on a bracket supplied Perpendicular to the wall Parallel to the wall Figure 2 Mounting of the amplifier 1 2 ...

Page 5: ...not use 192 168 1 10 since this is the IP address of the module to be configured To start the configuration of the module open your Web browser and type in the following direction http 192 168 1 10 The login prompt will appear on a screen see Figure 6 Figure 6 Login prompt Access to the Web interface is protected by user name and password The default user name and password is admin Enter the user ...

Page 6: ... number of the device Title changeable device title Software version module software version number Hardware version module hardware version number IP IP address of the Ethernet interface System time current system time Up time time passed from last power up or restart of the module Common status table The following module parameters are displayed at real time Supply voltage module power voltage i...

Page 7: ...P settings table MAC Address the physical address of the module Ethernet network card is displayed automatically IP Address enter the IP address that you wish to assign to the module This address must fall within the range of local network addresses Subnet mask enter the local network mask Gateway enter the IP address of the gateway This information is required only if you want to access the modul...

Page 8: ...nity string used for generating the agent traps Host IP 1 Host IP 2 IP addresses of hosts with SNMP managers where traps will be sent Download MIB file press this link to download the SNMP MIB file of the device Save the archive on your computer and extract the archive content Extracted MIB files are ready to use with SNMP manager software NOTE please read the user guide of SNMP manager software b...

Page 9: ...parameters window is displayed see Figure 13 Figure 13 Import parameters window Click on Click to select file and select the file containing configuration data that you wish to restore on the module Once you have selected the file click on the Upload button at the bottom of screen When the import process is finished a notification window will be displayed 9 6 4 Firmware upgrade If you wish to upda...

Page 10: ...he user settings User role Admin enables the user to change all module settings and manage other users Limited user role User enables the password change function only It is forbidden to modify the module settings for limited user Press the Remove button to remove user from the list NOTE By giving your personal password or user access account for another person you take full responsibility for all...

Page 11: ...PIC OPTICS CLASS 1M LASER PRODUCT Wave length 1270 1610 nm IEC60825 1 This product complies with the relevant clauses of the European Directive 2002 96 EC The unit must be recycled or discarded according to applicable local and national regulations Equipment intended for indoor usage only Functional earthing Connect to the main potential equalization This product is in accordance to following norm...

Reviews: