30
Technical Details
Description
M/U
Stella 24 C
Stella 24 CI
Stella 28
C
Stella 28
CI
Thermal Capacity
kW
24.3/11.3
24.3/11.3
Thermal power
kW
22.6/9.9
22.6/9.9
Nominal heat output
%
93.0
93.0
Heat output reduced by 30%
%
90.4
90.4
Heat loss through the flue when burner
on
%
5.2
5.2
Heat loss through the flue when burner
off
%
0.4
0.4
Consumption at nominal capacity G20
m
3
/
h
2.52
2.52
Consumption at nominal capacity
G30/G31
Kg/h
1.90/1.88
1.90/1.88
Flue gas temp. at nominal capacity
°C
132
132
Operation Temperature
°C
+50 / -10
+50 / -10
Heating system temperature
°C
38 – 80
38 – 80
Hot water temperature
°C
/
35 – 55
Hot water flow
∆
T=25°
°C
/
13
Hot water flow
∆
T=35°
°C
/
9.3
Minimum hot water extraction
l
/
2.3
Max. pressure hot water circuit
bar
/
8
Expansion tank capacity
l
7
7
Expansion tank pre-load pressure
bar
1
1
Heating system maximum pressure
bar
3
3
G20 methane gas nominal pressure
mbar
20
20
Min. pressure at G20 methane gas
nozzles
mbar
2.6
2.6
Max. pressure at G20 methane gas
nozzles
mbar
11.3
11.3
G30 / G31 LPG nominal pressure
mbar
28-30/37
28-30/37
Min. pressure at LPG nozzles
G30 / G31
mbar
6.0/8.2
6.0/8.2
Min. pressure at LPG nozzles
G30 / G31
mbar
27.6/34.2
27.6/34.2
Supply voltage/frequency
V/Hz
230/50
230/50
Input power
W
135
135
Protection Grade of electrical system
IP
X4d
X4d
Appliance type
/
C12 C32 N
C42
C52 / C62
C12 C32 N
C42
C52 / C62
Gas category
/
II
2H 3+
II
2H 3+
Number of nozzles
No.
12
12