background image

 

 

 

 

 

The list of components: 

Horizontal frame 

Adaptive, functional element which enables performance of all exercises. 

Base frame 

Base which enables to attach other components. 

Forearm crane 

Adaptive element (regulation of height and the inclination angle) that enables 

precise forearms placing  in the device structure.  

Forearm pads 

Adaptive element that adjusts the extension of the forearm pads  to set the 

upper limbs precisely in the device structure.  

Handles 

Ergonomic grip to perform therapeutic process. 

Weight 

Adaptive  element  that  enables    due  to  variable  geometry  to  define  proper 

weight for therapeutic process. 

Positioning knob (1) 

The knob that enables to block the abduction and adduction of the handle 

axis. 

Socket  (1) 

An element that enables to attach the weight (6) to the horizontal frame (1) 

during rotation resistance exercises of the forearm. 

Positioning pin  

An element positioning the weight in one of two sockets.  

10 

Positioning knob (2) 

An element that enables to adjust the weight through various positions of the 

weight. 

11 

Socket (2) 

An element that enables to attach the weight (6) during flexion and extension 

resistance exercises as well as  abduction and adduction of the wrists. 

12 

Positioning knob(3) 

A knob that adjusts the position of  the handle (5). 

13 

Positioning knob (4) 

An  element  locking  the  position  of  the  horizontal  frame  (1)  in  the  defined 

place. 

 

 

 

Summary of Contents for PICTOR

Page 1: ...1...

Page 2: ...2 PICTOR USER GUIDE V 1 0 R7...

Page 3: ...4 2 Explanation of symbols 5 3 Description of the device structure 5 4 Device setup 8 5 Advised exercises 9 6 Warnings 12 7 Contraindications and recommendations 12 8 Technical details 13 9 Warranty...

Page 4: ...PICTOR device enables the complex rehabilitation of the wrist based on self assisted active and resistance exercises This manual provides all the needed information concerning PICTOR device proper fun...

Page 5: ...safety statements are classified as follows Safety warnings and essential usage details Safety of exploitation warnings Unless followed may result in minor personal injury and or product property dam...

Page 6: ...THE DEVICE STRUCTURE Versatility of PICTOR possible settings enables to perform the therapy of various dysfunctions of wrist joint The structure of the device is explained on the model below 3 6 2 1...

Page 7: ...roper weight for therapeutic process 7 Positioning knob 1 The knob that enables to block the abduction and adduction of the handle axis 8 Socket 1 An element that enables to attach the weight 6 to the...

Page 8: ...the pads 4 Adjusting the height B is achieved by height positioning of the forearm crane 3 Adjusting the angle of the forearm pad towards the base C is performer through the release of the knob under...

Page 9: ...otation of the forearm Adjust the pads check point 4 Lock the positioning knob 13 Release positioning knob 7 Detach the weight to perform self assisted exercises 6 Attach the weight 6 to the socket 8...

Page 10: ...rform the resistance exercises 6 which according to the place where it is attached generates a different moment of strength The weight can be attached in one of two sockets 8 rotation 11 adduction and...

Page 11: ...ncrease or decrease the weight Release the knob 10 Move of flip the weight on the axis of the pin to define the proper weight Moving the weight using the knob 10 the value of the moment of the strengh...

Page 12: ...ton for full range of motion Before usage it is necessary to read the user guide first and definitely follow the terms advices and warnings User guide is also available at www termamed pl where tutori...

Page 13: ...ruchu odwodzenia i przywodzenia 55 Zakres ruchu nawracania i odwracania przedramienia 180 11 TECHNICAL DETAILS Manufacturer Model Version Class Dimensions Weight Terma Sp z o o PICTOR V 1 0 Class I ru...

Page 14: ...lude periodic maintenance and product reviews and in particular cleaning regulation performance control correction of operating errors or parameter programming and other actions that the user is respo...

Page 15: ...r work performed by the user in contravention of the user guide c Damages caused by the user s fault or ignorance d Product damages resulting from natural usage resulting from its use e Damage caused...

Page 16: ...filling the Incident application form given below it should be provided to the manufacturer by e mail termamed termamed pl or posted Name of institution Adress Institution contact details Contact deta...

Page 17: ...17 Incident effects Additional informations...

Reviews: