background image

TEREX UTILITIES TECHNICAL SUPPORT TEAM

PHONE:

 

1-844-TEREX4U (1-844-837-3948) 

 

| EMAIL:

 

[email protected]

MODEL(S):

TOOLS NEEDED:

SERVICE CALL:

NO.

PROGRAMMING TEH MOTOR 

CONTROLLER ON A 48V 

HYPOWER

TM

ALL TEREX UTILITIES UNITS 

EQUIPPED WITH THE 48V 

HYPOWER

TM 

SYSTEM

CURTIS PROGRAMMING DEVICE

PHILLIPS SCREWDRIVER

PROGRAMMING THE MOTOR CONTROLLER ON A 48V HYPOWER

TM

31

Summary of Contents for TECH TIP 31

Page 1: ...8 EMAIL UTILITIES SERVICE TEREX COM MODEL S TOOLSNEEDED SERVICECALL NO PROGRAMMINGTEHMOTOR CONTROLLERONA48V HYPOWERTM ALLTEREXUTILITIESUNITS EQUIPPEDWITHTHE48V HYPOWERTM SYSTEM CURTISPROGRAMMINGDEVICE...

Page 2: ...perform maintenance on this machine You read understand and obey manufacturer s instructions and safety rules employer s safety rules and worksite regulations applicable governmental regulations You h...

Page 3: ...ate the panel STEP 1 STEP 2 5 Remove the connector Select parameters STEP 3 STEP 4 7 Set Turn On Time Threshold Select Motor Item in Parameters STEP 5 STEP 6 9 Adjust speed settings Verify programming...

Page 4: ...he operator s manual for operational instructions STEP 2 Locate the panel displaying PTO hours and hybrid battery status This panel is typically installed in one of the rear compartments Once the pane...

Page 5: ...onnector at the back of the battery display and connect it to the Curtis Programming Device After approximately 10 seconds the Curtis Programming Device should power up STEP 4 Once the system boots up...

Page 6: ...select Output Parameters The variable Turn on Voltage should be set to 44 50V This value represents the voltage that triggers the engine to start and recharge the unit If this value is incorrect use...

Page 7: ...n On Time Threshold This threshold is the amount of time that the voltage must stay below the 44 50V before the system starts to recharge This value should be set to 5 seconds select it to modify the...

Page 8: ...P 31 RELEASED 03 14 2022 VERSION 1 0 STEP 6 CONTINUED Next choose Temperature Control The Sensor Enable variable in this screen should be set to OFF If it is ON select the variable to modify it PAGE 8...

Page 9: ...e RPM to produce 5 GPM at 1800 psi Then select RPM mode 2 and set it to get 7 GPM at 1800 psi For units with single flow hydraulics set RPM mode 2 to get the required flow 5 or 7 GPM at 1800 psi STEP...

Page 10: ...FOR FURTHER ASSISTANCE CONTACT THE TEREX UTILITIES TECHNICAL SUPPORT TEAM PHONE 1 844 TEREX4U 1 844 837 3948 EMAIL UTILITIES SERVICE TEREX COM...

Reviews: