PLATFORM LEVELING
The platform leveling is through a master/slave cylinder combination. It can be used for platform clean out
when no personnel are in the platform. It can also be used for rescue and removal of an injured operator.
OPERATION
Operate the level control from the lower control station when the platform is empty or is to be dumped for
clean out. Position the platform rotation in the stowed alignment along side the boom. Move the booms so
the boom tip is in an area clear of obstructions before tilting. When adjusting the level the platform must be
raised off the platform rest.
To adjust the platform level from the lower control station:
• Select lower controls.
• Move level control lever slowly in the direction shown on the decal as required to level.
To tilt the platform for clean out or rescue from the lower control station:
• Select the lower controls.
• Position booms so platform is at ground level and platform rotation (if equipped) is in the stowed
position.
• Rotate platform to stowed position before tilting.
• Move level control lever slowly in the direction shown on the decal to dump platform.
• Return the platform to normal level position before moving booms.
Operation from Upper control station:
The operation of the platform level from the upper control station must be done slowly and deliberately.
Perform all leveling operations while the platform is near the ground or just out of the stowed position. Do not
adjust the level position while elevated to a work position.
Do not allow anyone to operate platform tilt while occupants are in platform, except in
case of emergency. Serious injury or death could result from platform upsetting.