April 2017
34 GTH-1544 Part No.
57.0009.0610
Second Edition - Second Printing
DPF Ash Load Monitoring
(Deutz configuration)
During the whole engine lifetime, the DPF collects
ash which cannot be removed by regeneration
process.
The ash load leads to shortened regeneration
intervals and finally a filter replacement which is
signaled by the word “REPLACE” which appears
on the dashboard display.
Contact a qualified service technician to perform
this task.DPF Regeneration
Operating Instructions
(Perkins configuration)
In this configuration regeneration always starts
automatically.
Only when temperature is below -18°C, the
system is not able to activate the regeneration by
itself.
11
Dpf Alert indicator light, 11, starts blinking and
the operator has to start the DPF regeneration
following these instructions:
i
Select a safe outdoor parking location
firm level surface, clear of obstruction and
traffic.
ii Set the parking brake.
iii Move the transmission control lever to
neutral.
iv Warm up the engine stepping on the
throttle pedal until the Dpf Alert indicator
light comes off: this operation should take
about 15 minutes.