15
Alarm
code
Description
What to do
56
Page
18,32
Memory data not
reliable
• Switch the system off and on.
If the alarm persists, please, contact Technical
Assistance to:
•Verify that E2prom chip is fitted properly in its socket.
• Re-enter data and save them again
• Replace the E2PROM chip and recalibrate the
machine
15
Page
19, 20,
21,32
Angle sensor
reading lower than
the minimum value
• Verify that the wiring and the connectors are not in
short circuit.
If the alarm persists, please, contact Technical
Assistance :
• Verify the angle sensor integrity.
25
Page
19, 20,
21, 32
Angle sensor
reading higher than
the maximum value
•Verify that the cable or the connector wiring is not
open
If the alarm persists, please, contact Technical
Assistance :
• Verify the angle sensor integrity.
12
Page
25
Pressure reading of
the main cylinder
(bottom side) lower
than the minimum.
• Verify that the cable or the connectors wiring are not
in short circuit
If the alarm persists, please, contact Technical
Assistance :
• Verify the pressure transducer integrity
22
Page
26
Pressure reading of
the main cylinder
(bottom side) higher
than the maximum.
• Verify that the cable or the connector wiring are not
open
If the alarm persists, please, contact Technical
Assistance :
•Verify the pressure transducer integrity
ALARM CODES AND ACTIONS TO TAKE
ALARM CODES AND ACTIONS TO TAKE