TEREN DP17 Operation Manual Download Page 1

DP17 Flush Mount DP Display Unit/Transmitter-Operation Manual

                                                                 

Edition:A/1

 

DP17 Flush Mount DP Display Unit/Transmitter 

 

 
 
 
 
 

 
Applications& Features 

 

Designed for flush mount, measure and display environment 
differential  pressure  such  as  cleanrooms  in  electronics  or 
pharmaceutical  plants,  hospital  and  various  laboratories, 
etc. 

 

316L front panel, PMMA window, flat surface, no dust stays, 
good for all detergents, sanitizers and bactericides 

 

Strong EMI capability, compatible with the EMI requirements 
of EN61326-1 for industrial equipment 

 

Large LCD 

 

High  performance  sensor,  100%  interchangeable  sensor 
without re-calibration,1 channel 4~20mA output 

 

Compatible  to  any  DDC/PLC/SCADA  or  other  data  collect 
and control systems 

Specifications 

Different pressure sensor: 

DP 

DP17 

Accuracy 

1%FS

2%FS@0-25Pa

 

Range 

0~60/0-125 etc. 

see range table

 

Long term drift

 

<0.5%FS/Year 

Response time

 

0.5/1/5/10

settable

 

Thermal effect 

<0.05%FS/°C(Zero) <0.08%FS/°C(FS) 

Temp. comp.

 

0~50°C 

Medium Temp.

 

0~60°C 

Work Press.

 

10xFS(

overload

)

20xFS(

burst

Display:

 4 bits LCD (with backlight), display area 47x27mm, 

with word H 16mm and unit H 2mm 

Display panel material:

 PMMA 

Resolution:

 0.1Pa(or 0.001 in wc/mbar, 0.01mm wc etc., switchable)

 

Update time: 

<1s 

Power Supply:

 

16~28VAC/19~35VDC 

Consumption: 

<

 

1 VA   

Analog outputs:

1×4~20mA(3/4 wires), 

R

L

<500Ω

; over voltage 

and  reverse  polarity  protection;  accuracy  as  low  as 
0.3%FS(1.0%FS accuracy)

 

Process  connection: 

Built-in  DP  sensor:  2  conical  nozzles 

on back, Ø 5 mm tube connection 

Zero set: 

zero button / key 

Terminals: 

max Ø1.5mm

2

 

Work Environment: 

0~50°C, 0~95%RH (no cond.) 

Storage Environment: 

-10~70°C 

Front panel material: 

316L stainless steel, 1.5mm thick 

Back housing parts:

 fire retardant ABS+PC(UL94V-0) 

Protection: 

front panel IP65   

Weight:

 about 385g

 

Approval: 

CE, meet EN61326-1 for industrial equipment 

Models   

Model 

DP17 

 

 

 

Flush Mount DP Display Unit/Transmitter 

DP17M 

 

Range 

 

X   

 

Range selection 

Panel 
Port 

 

 

 

N/A 

 

 

 

1 pressure sampling screw on front panel 

Screw 

Hole 

 

 

 

0  N/A 

 

1  4 holes at corners, with SS screws 

 

Measuring Ranges 

Code 

UNIT & Range & Display Resolution 

Pa 

Pa 

kPa 

in w.c. 

mm w.c. 

mbar 

0-25 

25.00 

0.025 

0.100 

2.500 

0.250 

0-60 

60.00 

0.060 

0.250 

6.000 

0.600 

0-125 

125.0 

0.125 

0.500 

12.00 

1.250 

0-250 

250.0 

0.250 

1.000 

25.00 

2.500 

0-500 

500.0 

0.500 

2.000 

50.00 

5.000 

0-1000 

1000 

1.000 

4.000 

100.0 

10.00 

1. Set the 5 engineering units by button keys and the related LCD indicator will be on. 
2. 

For zero center models, add “Z” at the end of the model. Only ranges 1~5 have this selection. 

For example, DP171**Z, means the range is

 

-30-0-30Pa.   

 
.

 

 
 
 
 
 
 
 
 
 
 
 