Terbly T180C User Manual Download Page 15

XM1193-V1.0 -E

14

2. Press <Up/Down>, the display will show

NoDMXSta

.

3. Press< ENTER>, the display will show

NoDMXSta

.

4. The display show

Hold

,Press  <Up/Down>, the display will show “CloShut”,

“Auto”.

5. Press <ENTER> to confirm or press <MODE/ESC> to return to the main menu.

8.3.2 Service setting

Password——The Password for this function is “50”.

RDM UID—— With this function you can call up various submenus via RDM.

This device is RDM ready. RDM stands for "remote device management" and makes
remote control of devices connected to the DMX-bus. ANSI E1.20-2006 by ESTA specifies
the RDM standard as an extension of the DMX512 protocol.

Manual settings like adjusting the DMX starting address are no longer needed. This is

especially useful when the device is installed in a remote area.

RDM ready and conventional DMX devices can be operated in one DMX line. The RDM
protocol sends own packages in the DMX512 data feed and does not influence conventional
devices.

If DMX splitters are used and RDM control is to be used, these splitters must support RDM.

The number and type of RDM parameters depend on the RDM controller being used.

8.3.3 Disp Set

Off Time

With this function you can shut off the color LCD display after 2 to 59 minutes. Turn the
encoder in order to select the desired shut off time. The default is 5 minute.

Key Lock

With this function you can activate the automatic keylock status. If this function is activated,
the keys will be locked automatically after exiting the edit mode for 15 seconds. keeping
press the [MENU] key for 3seconds if you do not need this function.

1

Access the main menu.

2

Press <Up/Down>, the display will show

Key Lock

.

3

Press< ENTER>, the display will show

Key Lock

.

4

The display show

OFF

,Press   <Up/Down>, the display will show

ON

.

5

Press <ENTER> to confirm or press <MODE/ESC> to return to the main menu.

8.3.4 Temp C/F

With this function, Display the temperature for Celsius or Fahrenheit.

1

Access the main menu.

2

Press <Up/Down>, the display will show

Temp C/F

.

3

Press< ENTER>, the display will show

Temp C/F

.

4

The display show

Celsius

,Press   <Up/Down>, the display will show “Fahrenheit”.

5

Press <ENTER> to confirm or press <MODE/ESC> to return to the main menu.

Summary of Contents for T180C

Page 1: ...LED PROFILE USER MANUAL T180C KEEP THIS MANUAL FOR FUTURE NEEDS...

Page 2: ...aluDisp 11 8 1 3 SetSlave 12 8 1 4 AutoProg 12 8 2 Info 12 8 2 1 TimeInfo 12 8 2 2 TempInfo 13 8 2 3 Soft Ver 13 8 3 Persnal 13 8 3 1 Stat Set 13 8 3 2 Service setting 14 8 3 3 Disp Set 14 8 3 4 Temp...

Page 3: ...ualified follow carefully the instructions of this manual INTRODUCTION Thank you for having chosen this professional LED PROFILE You will see you have acquired a powerful and versatile device Unpack t...

Page 4: ...ng condensation could damage the device Leave the device switched off until it has reached room temperature This device falls under protection class I Therefore it is essential that the device be eart...

Page 5: ...This fixture is only allowed to be operated with the max alternating current which stated in the technical specifications in the last page of this manual Lighting effects are not designed for permane...

Page 6: ...er stand directly below the device when mounting removing or servicing the fixture The operator has to make sure the safety relating and machine technical installations are approved by an expert befor...

Page 7: ...urface without fixing remaining steady no matter what the angle of the head Fully operational in any mounting position hanging upside down side mounted or set on a flat level surface etc When clamp mo...

Page 8: ...XM1193 V1 0 E 7 Dimensional Drawings...

Page 9: ...ccidental damage and or injury in the event the clamp fails Overhead mounting requires extensive experience including amongst others calculating working load limits a fine knowledge of the installatio...

Page 10: ...s to run a long distance or is in an electrically noisy environment such as in a discotheque it is recommended to use a DMX terminator This helps in preventing corruption of the digital control signal...

Page 11: ...he last keypress UP screen will flash when pressing this key in normal mode the adress value will increasing Keep pressing this key the address value will increase rapidly it will exit from flash 60 s...

Page 12: ...program Program in loop Save and exit EditScen Scene001 Scene250 Auto ScenTime InByOut Auto xxx TIME xx xs Save and automatically return manual scenes edit RecCntrl XX XX Automat scenes rec Default se...

Page 13: ...o Cur Time With this function you can display the temporary running time of the device from the last power on The display shows XXXX XXXX stands for the number of hours The counter is resetted after t...

Page 14: ...ius 1 Access the main menu 2 Press Up Down the display will show Head Temp 3 Press ENTER the display will show Head Temp 4 The display show XXX C F 5 Press ENTER to confirm or press MODE ESC to return...

Page 15: ...rol is to be used these splitters must support RDM The number and type of RDM parameters depend on the RDM controller being used 8 3 3 Disp Set Off Time With this function you can shut off the color L...

Page 16: ...to return to the main menu 8 4 ManCntrl 8 4 1 ManCntrl With this function you can adjust the lamp more easily All effects will be canceled the shutter opens and the dimmer intensity will be set to 100...

Page 17: ...for the Program Run 8 7 2 EditProg With this function you can edit the internal programs 8 7 3 EditScen With this function you can edit the scenes of the internal programs 8 7 4 RecCntrl The LED PROFI...

Page 18: ...Color Macro 02 16 23 Color Macro 03 24 31 Color Macro 04 32 39 Color Macro 05 40 47 Color Macro 06 48 55 Color Macro 07 56 63 Color Macro 08 64 71 Color Macro 09 72 79 Color Macro 10 80 87 Color Macr...

Page 19: ...2 63 LEDS ON 64 95 Strobe Effect SLOW to FAST 96 127 LEDS ON 128 159 Pulse Effect In Sequences 160 191 LEDS ON 192 223 Random Strobe Effect SLOW to FAST 224 255 LEDS ON 6 8 10 15 DIMMER INTENSITY 0 25...

Page 20: ...on spot and usage have to be adhered by a skilled installer and any safety problems have to be removed In order to make the lights in good condition and extend the life time we suggest a regular clean...

Page 21: ...C 100 240V 50 60Hz Power consumption 200W Packing dimensions 56 5 x 38 5 x 33 5 cm Net weight 7 2 KG Gross weight 11 5KG Remark errors and omissions for every information given in this manual excepted...

Page 22: ......

Page 23: ......

Page 24: ......

Reviews: