PT330W-R User Manual XM1147-V1.0-NR
9
WARNING!
THE BULB SHOULD BE REPLACED WHEN DAMAGED OR DISTORTED BY
HEAT.
CAUTION!
DISCONNECT THE FIXTURE FROM POWER AND ALLOW IT TO COOL FOR
ONE HOUR
Procedure:
1) Please put the fixture on a smooth desk release the screw A B C
.
Then open the plate
for lamp-socket
.
2) Before taking off the lamp
please release the two red wires which connect to the lamp
( Picture No
.
1 marked a)
.
3) Please press the point which two red arrows point at like what picture No
.
2
shows
.
Then push forward
lamp can be took off
.
Attention
wrap the lamp with soft
cloth which go with the lamp to avoid your finger touching the glass of lamp directly
.
4) Replace lamp
.
Please be noted that there's only one installation direction for the lamp
.
Make sure the replaced lamp has the same installation direction with the old one
.
After
that
please confirm whether it is fixed
.
5) Cover the plate of lamp socket and tighten screw A
B
C
.
6) Please reset the lamp life-time
.
Otherwise it is likely to trigger the protecting firmware
to make the replaced lamp close itself automatically
.
Please remember the lamp is not a hot-restrike lamp
you must wait for approximately 10
minutes after having turned off the lamp before you can turn it back on again
.
CAUTION!
DO NOT OPERATE THIS DEVICE WITH OPEN COVER