Chapter 2 Installation
BU 802 Battery Backup Unit Installation
2-24
TA 102/202 Technical Support Guide
Power Up and Check
To power up and check out the BU 802 Battery Backup Unit, do the following:
1. Verify that all signal cables have been connected to the TA-102/202 eMTA.
2. Locate the Power Adapter that came with the modem.
3. Using Figure 2-18 as a guide, align the key groove of the Power Adapter DC Output
connector with the key slot in the BU 802 voltage input jack, then push the connector
into the jack so the cable is firmly connected
Figure 2-18 Connecting the Power Adapter to the BU 802 Battery Backup Unit
4. Plug the male end of the Power Adapter power cord into an AC outlet to power up the
BU 802 and the TA-102/202 eMTA.
5. Verify the BU 802 Battery Status LED is a solid green color to indicate the BU 802
receiving DC power from the AC Power Adapter.
6. After powering up the BU 802, wait 10 minutes, then disconnect the Power Adapter
power cord from the AC outlet.
7. Verify the BU 802 Battery LED is flashing green and the TA-102/202 eMTA Power
LED is flashing amber, indicating the TA-102/202 eMTA is operating from battery
backup power.
8. Reconnect the Power Adapter power cord to the AC outlet.
POWER ADAPTER
DC VOLTAGE
OUTPUT CONNECTOR
TERAYON DOCSIS MODEM
MODEL TA-102 or TA-202
Tera
yon
AC
Adaptor
POWER ADAPTER
BU 802 BATTERY
BACKUP UNIT
DC VOLTAGE
INPUT JACK