Tepex PLFS 50 User Manual Download Page 4

 

26

0±2

228±1

5.  MONTAŽA

  

5.  INSTALATION

 

 

 
Montaža  i  instaliranje  svjetiljke  se  izvodi  prema  podacima  na 
natpisnim  pločicama  na  svjetiljci,  ovim  i  dodatnim  uputama 
proizvođača,  nacionalnim  Propisima  i  Pravilnicima,  kao  i  prema 
općenito priznatim pravilima tehnike. Samo uz taj uvjet osigurana 
je  tipnim  certifikatom  potvrđena  protueksplozijska  zaštita 
svjetiljke.  
Montaža  svjetiljke  na  podlogu  vrši  se  preko  nosača  vijčanim 
priborom M6. 
Otvaranje kućišta se vrši odvrtanjem četiri vijka M5x25. Priključni 
kabel se uvodi u kućište kroz predviđene uvodnice. Pri tome treba 
provjeriti  da  su  kabeli  čisti  i  neoštećeni.  Posebnu  pažnju  treba 
posvetiti  odabiru  unutarnjeg  brtvenog  prstena  uvodnice  prema 
vanjskom  promjeru  kabela.  Pritisnu  maticu  uvodnice  i  tijelo 
uvodnice  treba  pritegnuti  nazivnim  momentom.  Neiskorišteni 
uvod,  na  isti  način,  obavezno  treba  zatvoriti  čepom.  Električni 
priključak  izvodi  se  spajanjem  mrežnih  vodiča  (L,  N,  PE)  na 
priključne stezaljke i unutarnje uzemljenje. 
Zatvaranje  kućišta  se  izvodi  na  opisani  način,  suprotnim 
redoslijedom radnji. 

 

Installation and putting into operation have to be done according to 
technical and certification data on warning label on lamp, this user 
manual,  national  regulations  and  laws.  Only  with  that,  explosion-
proof  protection  of  bulkhead  light  fitting  is  ensured  with EU-type 
examination certificate.  
 
Installation  of  lamp  (on  wall  or  ceiling)  is  done  with  steel 
brackets with M6 screws. 
Opening  of  Ex  e  enclosure  is  done  by  unscrewing  four  screws 
M5x25.  Special  attention  must  be  dedicated  to  selection  of  inner 
gasket  sealing  ring  of  Ex  e  cable  glands  according  to  diameter  of 
connecting  cable.  Pressure  nut  and  intermediate  gland  must  be 
tightened  with  nominal  torque.  Unused  cable  entries  must  be 
closed  with  plug.  The  electric  connecting  is  performing  by 
connecting  power  supply  cable  (L,  N,  PE)  on  the  connection 
terminals and terminal for internal grounding.  
The  closing  of  the  Ex  e  enclosure  should  be  done  by  a  reverse 
sequence of action. 

 

 

6.  DIMENZIJE

 

6.  DIMENSIONS

 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

7.  PREGLED, ODRŽAVANJE, POPRAVAK I OBNAVLJANJE 

7.  INSPECTION, MAINTENANCE, REPAIR AND OVERHAUL

 

 

 
Potrebno je obavljati preglede i održavati sve dijelove uređaja o 
kojima ovisi protueksplozijska zaštita sukladno normi  EN 60079-
17,  općim  i  posebnim  uputama  proizvođača    i  Pravilnicima 
korisnika, a naročito: 

-

 

da su kućište, svi dijelovi kućišta, zaštitno staklo i brtve bez 
puknuća i oštećenja, 

-

 

da je kućište potpuno zatvoreno sklopom zaštitnog stakla, 

-

 

da  su  uvodnica,  čep,  vijci  kutnika  brtve,  vijak  stezaljke  za 
uzemljenje pritegnuti nazivnim momentom. 

Popravak, obnavljanje ili pregradnju  kućišta obavlja proizvođač ili 
od  proizvođača  ovlaštena  pravna  osoba,  originalnim  dijelovima 
prema  proizvodnoj  dokumentaciji,  a  sve  sukladno  normi  EN 
60079-19. 

 

Inspections  are  carried  out  in  accordance  with  EN  60079-17, 
general  and  special  conditions  of  manufacturer  and  users 
Regulations  and  includes  supervision  of  parts  on  which  the 
explosion protection depends, especially: 

-

 

that  the  housing,  all  part  of  housing,  protective  glass  and 
gasket are without rupture and damage, 

-

 

that the housing is completely closed with set of protective 
glass 

-

 

that the cable gland, plug, connecting terminals, screws of 
protective grid are tightened with nominal torque. 

All  the  repairs  must  be  performed  by  the  manufacturer  or  the 
manufacturer's  authorized  personal  using  the  original  parts 
according to the product documentation, all in accordance with 
EN 60079-19. 

Summary of Contents for PLFS 50

Page 1: ...u cijelo vrijeme Provjeravati provođenje ove Upute i svih drugih sigurnosnih uputa korisnika W A R N I N G The user manual contains basic information about the product Mounting installation usage and maintenance should be carried out under this user manual to provide and ensure safe operation within the nominal characteristics This user manual complement national Regulation and Standards The respo...

Page 2: ...2G Ex db eb op is IIC T6 Gb II 2D Ex tb op is IIIC T80 C Db Temperatura okoline 40 20 C Ta 50 55 60 C Mehanička zaštita IP 66 Otpornost na udar IK 08 Klasa zaštite I PE zaštitno uzemljenje Nazivni napon Un 230 V AC 50 Hz Radni napon 90 305 V AC 127 431 V DC Nazivna snaga Pn 35 W PLFS 50 LED 1 50 W PLFS 50 LED 2 60 W PLFS 50 LED 3 Faktor snage 0 95 LED izvor BXRC 40E10K0 D 7X Bridgelux CLU04J 1818C...

Page 3: ...well OVP protection IEC 61000 4 5 EN 62031 3kV 1min impulse overvoltage 8 20μs 6kV 3kA OCP protection 2A T IEC 60127 OTP protection Tsmax 80 C resettable IEC 60730 1 Luminous flux LED module 5020lm PLFS 50 LED 1 7180lm PLFS 50 LED 2 8610lm PLFS 50 LED 3 Luminous flux light fitting 4520lm PLFS 50 LED 1 6460lm PLFS 50 LED 2 7750lm PLFS 50 LED 3 Light output ratio of luminaire 0 9 LED modul efficacy ...

Page 4: ...er of connecting cable Pressure nut and intermediate gland must be tightened with nominal torque Unused cable entries must be closed with plug The electric connecting is performing by connecting power supply cable L N PE on the connection terminals and terminal for internal grounding The closing of the Ex e enclosure should be done by a reverse sequence of action 6 DIMENZIJE 6 DIMENSIONS 7 PREGLED...

Page 5: ...u informaciju o proizvodu Nadopunjuju ju odgovarajući nacionalni zakoni i propisi Proizvodnja uporaba certifikacija i nadzor određene su na nacionalnoj razini a Pravilnikom o opremi i zaštitnim sustavima namijenjenim za uporabu u prostorima ugroženim eksplozivnom atmosferom NN br 33 16 odnosno EU Direktiva ATEX 2014 34 EU i b Pravilnikom o najmanjim zahtjevima sigurnosti i zaštite zdravlja radnika...

Page 6: ...n obligations This statement has the force of Warranty sheet 12 OZNAČAVANJE 12 MARKING Protueksplozijski zaštićena ovjesna svjetiljka PLFS 50 LED označena je natpisnom pločicom upozorenja na kućištu svjetiljke Explosion protected pendant light fitting PLFS 50 LED is marked with warning label on housing of light fitting natpisnom pločicom na poklopcu Ex eb komore marking label on cover of terminal ...

Reviews: