background image

Programming Parameter:

Selecting Time Base & Modes:

3

Prog. end

Sec: Second : 000.0....599.9

Min: Minute : 00.00....99.59

Hour: Hours : 00.00....99.59

Select mode of operation.

Power-on Reset:

Yes: Timer SET value is reset.

No: Loads Timer value & OUT status 

at the latest power failure after

the first power on.

Enter fixed password; 162.

Lower

Display

Lower

Display

Lower

Display

Lower

Display

Programming Timer SET Value:

SET

Press for 3 sec.

Upper Display

t.SEt

Set Value

Upper Display

Upper Display

Set Value

Set Value

SET

SET

Prog. end

t.oFF

Prog. end

t.on

If Out is selected as; 0, 2, 3, 4.

Second : 000.0....599.9

Minute : 00.00....99.59

Hours : 00.00....99.59

If Out is selected as; 1.

Second : 000.0....599.9

Minute : 00.00....99.59

Hours : 00.00....99.59

If Out is selected as; 1.

Second : 000.0....599.9

Minute : 00.00....99.59

Hours : 00.00....99.59

Lower

Display

Lower

Display

Lower

Display

+

SET

Press for 3 sec.

Upper Display

Upper Display

Upper Display

Upper Display

SET

t.bAS

Sec, Min, Hour

SET

Out

0....7

SET

P.rES

Yes, no

SET

CodE

Enter 162

Front Panel RESET:

Press for 2 sec.

RESET

Out = 1

Summary of Contents for ERD-72M

Page 1: ...les Take precauitons against environmental conditions like humidity vibration pollution and high low temperature during installation Use a fuse slow 250mA 250VAC on supply input of the device Use appropriate cables for supply connections Apply safety regulations during installation Warning Panel Hole Size Display Inputs Gate Input Output Time base Modes Sensor Supply Out Supply Voltage Pow Consump...

Page 2: ...e free wheeling diode to protect SS Out Notes N L1 L2 L3 2A Load1 2A Load2 3 15 14 16 17 18 19 20 4 5 6 7 8 9 10 100 240 VAC 50 60Hz 6VA no Out1 nc no Out2 nc 12V 50mA START RESET GATE SS Out1 SS Out2 GND Digital Timer ERD 72M 30Vdc Max 30Vdc Max SSR SSR 72mm 72mm 15mm 74mm 6mm ...

Page 3: ...or 3 sec Upper Display t SEt Set Value Upper Display Upper Display Set Value Set Value SET SET Prog end t oFF Prog end t on If Out is selected as 0 2 3 4 Second 000 0 599 9 Minute 00 00 99 59 Hours 00 00 99 59 If Out is selected as 1 Second 000 0 599 9 Minute 00 00 99 59 Hours 00 00 99 59 If Out is selected as 1 Second 000 0 599 9 Minute 00 00 99 59 Hours 00 00 99 59 Lower Display Lower Display Lo...

Page 4: ...e ON Out1 2 are OFF when RESET input is ON Out1 2 become ON when START input is ON Out1 2 become OFF t SEt after START input is triggered ON OFF Out1 2 are OFF when RESET input is ON Mode 4 Follow ON Delay Start Out1 Out2 t SEt Out1 is ON when Start input is ON Out2 becomes ON t SEt after START input is ON Out1 2 are OFF when START input is OFF Out1 2 are OFF when RESET input is ON Mode 5 Delayed ...

Reviews: