OPERATION
6600 330950 (4--03)
40
STARTING THE MACHINE
1. LPG powered machines: Open the liquid
service valve slowly.
NOTE: Opening the service valve too quickly may
cause the service check valve to stop the flow of
LPG fuel. If the check valve stops the fuel flow,
close the service valve, wait a few seconds and
open the valve slowly again.
2. You must be in the operator’s seat with the
directional pedal in neutral, and your foot on
the brake pedal or with the parking brake
set.
FOR SAFETY: When starting machine,
keep foot on brake and directional pedal
in neutral.
3. Turn the ignition switch key clockwise until
the engine starts.
NOTE: Do not operate the starter motor for more
than 10 seconds at a time or after the engine has
started. Allow the starter to cool between starting
attempts or damage to the starter motor may
occur.
4. Allow the engine and hydraulic system to
warm up three to five minutes.
WARNING: Engine emits toxic gases.
Severe respiratory damage or
asphyxiation can result. Provide
adequate ventilation. Consult with your
regulatory authorities for exposure
limits. Keep engine properly tuned.