SpeedScrub 2401/2601 (04–97)
CAUTION: Do not continue to run
machine when battery meter needle is in the
red zone, battery damage will result.
11. While cleaning, view clear tube gallon marker
for remaining cleaning solution. Each mark on
hose indicates five gallons / 19 liters.
12. When solution tank runs dry, drain recovery
tank
. (See DRAINING TANKS).
STOPPING MACHINE
1.
Turn off brush/solution switch, raise brushes
and continue to vacuum until all dirty water is
consumed.
2.
Release control grips.
3.
Raise squeegee and scrub head.
4.
Turn off switches and remove key.
5.
Set parking brake, pull lever backwards to
set. (Figure 20)
FIG. 20
ATTENTION: Before leaving machine,
stop on level surface, set parking brake, turn
off machine and remove key if left unattended.
EMERGENCY STOPPING
To stop machine in case of an emergency, hit the
red power kill button located at rear of control
console. The power kill button immediately stops
all power to machine.
(Figure 21)
To reset power kill button, shut off all switches and
turn kill button to the right. Resume to normal
operation.
FIG. 21
CIRCUIT BREAKERS
The SpeedScrub models are equipped with (4)
circuit breakers to protect machine from damage.
If circuit breakers should trip, the breakers will not
reset immediately upon tripping. Determine
reason why breaker tripped, allow motor to cool
and reset.
Brush motor circuit breakers will trip due to
excessive overload on pad. Reduce pad pressure
or replace pad if breaker should trip. Brush motor
circuit breakers (15amp) are located near charger
plug.
The main (10amp) and drive/vacuum (35amp)
circuit breakers are located at rear of machine.
(Figure 22)