OPERATION
14
Tennant 5200 Battery (01–02)
TROUBLE SHOOTING – CONTINUED
PROBLEM
CAUSE
SOLUTION
Poor water pick up.
Recovery tank is full.
Empty recovery tank.
Ball float shutoff screen inside
recovery tank is clogged.
Remove screen and clean.
Squeegee is clogged with debris.
Clean squeegee.
Squeegee blades are worn.
Replace squeegee blades.
Squeegee thumbscrews are loose.
Tighten thumbscrews.
Vacuum hose connections are
loose or hose has a hole.
Push vacuum hose cuffs firmly on
connections. Replace hose if
damaged.
Vacuum hose is clogged with
debris.
Remove clogged debris.
Tank gasket is defective.
Replace tank gasket.
Recovery tank water inlet is
plugged. Inlet is located at bottom
of recovery tank.
Empty recovery tank and tilt it
sideways to locate inlet hole,
remove clogged debris.
Drain hose plug is loose.
Tighten drain plug.
Clear recovery tank lid is loose.
Tighten lid.
Vacuum motor is loose.
Tighten down vacuum motor. Do
not over tighten and damage motor.
Battery charge is low.
Charge batteries. Do not run
machine when battery meter is in
the red zone.
SPECIFICATIONS
Model
5200
LENGTH
1194 mm (47 in)
WIDTH
559 mm (22 in)
HEIGHT
965 mm (38 in)
WEIGHT
146 Kg (315 lb)
SOLUTION TANK CAPACITY
38 L (10 gal)
RECOVERY TANK CAPACITY
45 L (12 gal)
CLEANING PATH WIDTH
508 mm (20 in)
BRUSH MOTOR
.75hp, 220 rpm, 24v, 20A, 560w
VACUUM MOTOR
.5hp, 2 stage, 353w, 14A, 24v
WATER LIFT
1118 mm (44 in)
BATTERIES
2–130A/hr, 12v deep cycle
RUN TIME on full charge
2.47 hours
DECIBEL RATING AT OPERATOR’S EAR, INDOORS ON TILE
70dB(A)