Summary of Contents for TM-BX

Page 1: ...TCNMARS Thermometer TM 8ON TM 82N TM 83N TM 84N Users Manual HB2TMSONOOOO ...

Page 2: ... is a digital thermometer use for thermocouple type Build in microprocessor and high resolution analog to digital converter chip The thermocouple probe has fast response measure wide ranges easy change shape and popular prices This popular used to industry and homes ...

Page 3: ...ay and stoP uPdate 4 Offset changed 0 0 5 Enable maximum minimum and average record and current mode indication 6 Enter the SETUP mode sYmbol 7 Symbol of Limit is ALARM function enabled Symbol of Hi Lo is state of alarm detonated B Tl subtract to T2 function enabled 9 Primary display and state of channels temperature unit and thermocouPle tYPe 1O Secondary display and state of channels temperaiure...

Page 4: ... ln the setup mode down select function T1 minus T2 Temperature function enable or disable Press and hold T1 with T2 display location swap TM B2N 84N 5 lnstruction for Use Temperature Unit Select C F K User can change temp unit to between Celsius C Fahrenheit F and Kelvin K Press t9key to change follow the figure circles C F S K G K only TM 83N B4N The device will auto save unit before shutdown be...

Page 5: ...Freeze Display and Stop Update HOLD User can or rGkey to freeze display and stop update temperature read pr G key again to unfreeze When the HOLD function is enable all function keys was useless except for power key Deducting Relative Reading Function REL User can Or r key to show deducting relative reading This function provides display becomes 0 Save the previous reading as the standard relative...

Page 6: ... disable or enable the auto power off function Please press nO no OQlouto off key Power On Off tr k y to turn on or turn off the power ln the SETUP mode can t turn off the power Please leave the SETUP mode lf can t turn on the power please check battery connect normal and power enough Changing the Offset User can adjust the offset to compensate for the error of specific thermocouple 1 Press und Io...

Page 7: ...Press leftS ano right tey to select digit and negative symbol s eress 1sET Key to save setting value lnto set T1 Lo 4 Repeat step 2 to set T1 Lo temperature u r 1rET Key to save setting value and leave setup mode TM 82N B4N into the set T2 Hi 6 Repeat step 2 to set T2 Hi temperature r r 1rET Key to save setting value lnto set T2 Lo 8 Repeat step 2 to set T2 Lo temperature n r 1aET Key to save sett...

Page 8: ...Power 26mW Operating temperature humidity S Cto 40 C below 80 RH Storage temperature humidity 10 C to 60 C below 70ol0 Weighl About 170g Dimensions 130 L 56 W 38 H mm Accessories User s manual 9V battery K Type thermocouple 7 Battery Replacement Turn off the instrument Remove the battery cover Replace the battery lnstall the battery cover 8 Safety Precaution For cleaning the instrument use a soft ...