TM-93
14
Environmental status display
:
Safe zone
green
average zone
yellow
danger zone
red
The preset color zones are for reference only: Users can adjust
the yellow high and low zones.
Dose rate Range
RF strength
The Green zone
≦0.19
μ
sv/h
0~0.03mW/m
²
;0~0.1V/m
The Yellow zone
0.2~0.5
μ
sv/h
0.1~2.0 V/m
The Red zone
>0.51
μ
sv/h
≧2.1V/m
Battery Life
:
Approximately 10 hours.
Power : 9V Alkaline battery
( NEDA 1604
、
IEC 6F22 or JIS
006P).
。
Operation temperature and humidity:
5 to 40
o
C(41 to 104
o
F);
under 80%RH.
Storage temperature and humidity: -10 to 60
o
C
(14 to 140
o
F);
under 70% RH.
Dimensions:115x60x31mm(length x width x height).
Weight: Approximately 170 grams.
External power supply:
DC4.8~5.2V current
≧
500mA.
will be displayed on the screen when external
USB power is supplied.
The inserted USB cable is also viewed as an
antenna; do not let the USB cable exceed the top of
the button when performing tests. If RF strength
test is performed when it exceeds the top of the
button, the value read is invalid.