- 8 - 

8  Maintenance 

1. When  the  When 

    symbol  is  displayed  on 

the LCD, it means that there is insufficient power; 
please change the battery immediately in order to 
ensure its accuracy.   

2. Do not place the meter in locations that have high 

temperature,  humidity  or  that  are  exposed  to 
direct sunlight. 

3. Remember  to  turn  off  the  power  after  usage; 

remove the battery if not used for a long period of 
time  in  order  to  prevent  battery  leakage  and 
causing damages to internal components. 

4. When  the  instrument  failure,  only  by  the 

authorized  service  provider  or  return  the  original 
repair.   

Battery Replacement

 

1. Turn off the power. 
2. Open the battery cover at the back of the meter, 

remove the batteries. 

3. Please insert six new 9V batteries according to 

the polarities. 

4. Put the battery cover back in place. 

 

 

 

Summary of Contents for TM-104

Page 1: ...TM 104 Sound Level Meter User s Manual HB2TM1040000 ...

Page 2: ...ty 1 4 Meter description 2 5 Operation 3 5 1 Disable auto power off 4 5 2 Maximum and Minimum hold 4 5 3 Data hold 4 5 4 94dB Calibration 5 6 General Specifications 6 7 Electrical Specifications 7 8 Maintenance 8 9 Battery Replacement 8 10 Disposal 9 ...

Page 3: ... the meter and its components Compliance with European Directive Do not operate in environments with flammable gas or humid environments Do not place the meter in locations with high temperature humid or exposed to direct sunlight Operating altitude 2000 meters below sea level Operation environment Indoor use contamination level class 2 EMC EN61326 1 CISPR 11 Group 1 Class B Class B Equipment is s...

Page 4: ... description 1 Microphone 2 LCD display 3 A C weighting select button 4 Power button 5 Maximum and Minimum hold button 6 Data hold button 7 Time weighting select button 8 Tripod nut 9 Battery cover 10 Windscreen ...

Page 5: ...el wherein click to switch the modes Press to capture the maximum or minimum noise level and lock the readings When measuring noise with the sound level meter by hand keep the distance between the microphone and the sound source by about 1 1 5 meters Warning Wind blowing across the microphone would bring additional extraneous noise Once using the instrument in the presence of wind with speed highe...

Page 6: ...to disable or enable as needed 5 2 Maximum and Minimum hold Click for less than 1 second to view the maximum and minimum values cyclically while pressing and for switching frequency weighting and time weighting Press and hold for more than 1 second to quit the function 5 3 Data hold Click to enable or disable the data hold function When HOLD is activated all buttons will be disabled except for ...

Page 7: ...B 1KHz sine wave Press and hold for more than 1 second and enter the 94dB correction function Press for auto calibration Press to select frequency weighting Use the to manually adjust the deviation value 3 5dB Press to quit the 94dB correction function Auto correction range is 90 5 97 5dB The meter has been calibrated as ex factory The calibration period is recommended as 1 year ...

Page 8: ...old Overloading OVER or UNDER Low battery indication Battery 9V NEDA 1604 IEC 6F22 or JIS 006P Battery life About 50 hrs alkaline Battery Standby power consumption 9uW Operating power consumption 90mW Operation temperature and humidity 5 to 40o C 41 to 104o F 80 RH Storage temperature and humidity 10ºC to 60ºC 14 to 140 70 RH Weight about 200g including battery Dimension 235 L x 56 W x 40 H mm ...

Page 9: ... IEC 61672 1 class 2 IEC651 Type2 ANSI1 4 Type2 Microphone 1 2 inch Electret condenser microphone Dynamic Range 50 dB Measuring range 35 130 dBA 40 130 dBC Frequency response 31 5 Hz 8 KHz Resolution 0 1 dB Time weighting FAST 125 ms SLOW 1s Frequency weighting A C Accuracy 1 8 dB reference SPL 94 dB 1KHZ ...

Page 10: ...member to turn off the power after usage remove the battery if not used for a long period of time in order to prevent battery leakage and causing damages to internal components 4 When the instrument failure only by the authorized service provider or return the original repair 9 Battery Replacement 1 Turn off the power 2 Open the battery cover at the back of the meter remove the batteries 3 Please ...

Page 11: ...9 10 Disposal Note This symbol indicates that the meter and its accessories must be separated and processed properly ...