background image

www.element14.com
www.farnell.com
www.newark.com
www.cpc.co.uk
www.mcmelectronics.com

TM

TM

Page <1>

V1.0

12/04/13

Rework Station 

Instruction Manual

SS-952C-F Series

SMD Rework Station

Instruction Manual

Summary of Contents for SS-952B-F Series

Page 1: ...www element14 com www farnell com www newark com www cpc co uk www mcmelectronics com TM TM Page 1 V1 0 12 04 13 Rework Station Instruction Manual SS 952C F Series SMD Rework Station Instruction Manual ...

Page 2: ...hot air gun is docked on the handle and remained idle for 5 minutes Once the hot air gun is released from the handle during sleep the unit will automatically switch back to previous working temperature and airflow level conditions without the need for manual intervention Functions and Features Micro processorcontrolled ESD safe unit Fast heating response Easytoadjust temperature and airflow contro...

Page 3: ...Air Nozzles 1124 1130 1196 1197 1 pc Z003 Hot Air Gun Holder 1 pc Vacuum Suction Pen For SS 952 only 1 pc G001 IC Popper for SS 952 only 1 pc Power Cord 1 pc Instruction Manual Specifications Station Dimensions 188 W 127 L 244 D mm Weight 3 8Kg Power Input 110 220V AC 50 60Hz Power Consumption 500W Temperature Range 100 C 480 C Heating Element Type Metal Heating Core Pump Motor Type Diaphragm Spec...

Page 4: ...is equipped with auto shutoff ability when temperature gets too high and automatically turns on when temperature dropped to a safe level Handle with Care Never drop or sharply jolt the unit Contains delicate parts that may break if unit is dropped Disconnect the plug from the power source if the unit will not be used for a long period Turn off power during breaks if possible Use only genuine repla...

Page 5: ...ation Instruction Manual Legend A Product Name B1 Temperature Meter B2 Airflow Level Meter C1 Temperature Control Up C2 Temperature Control Down C3 Airflow Control Up C4 Airflow Control Down D Reset Button E Hot Air Output F Hot Air Gun Switch G Airflow Gauge H Power Switch I Temperature Adjustment Indicator Panel Controls ...

Page 6: ...at How to use the RESET button The RESET button button D from the control panel can be used to reconfigure temperature and airflow level settings Once pressed the system will temporarily switch to stand by mode then start the device using default temperature and airflow level values of 100 C and 51 respectively Pressing the RESET button also removes previously configured system values Note for SS ...

Page 7: ...nel will initially display the product name in a scrolling manner like below The temperature heat and air level panel will both display OFF afterwards 2 Start the hot air gun by selecting Reworking from the Hot Air Gun switch F 3 The system will operate at 100 o C temperature and 51 on the airflow level meter by default You will also notice that the metal ball inside the airflow gauge is positione...

Page 8: ... Air Gun switch 8 This will start the auto cooling function by blowing air at full speed to accelerate cooling down of the hot air gun 9 The cooling function will automatically stop once the temperature of the hot air gun reaches 90 C as displayed from panel B1 10 The panel will display OFF on both the temperature and airflow level indicating that the device can already be switched OFF 11 Turn OFF...

Page 9: ... C1 or C2 5 Press C4 to confirm 6 The device will start counting down when the hot air gun is docked on the handle Once countdown is finished and the hot air gun still docked the device will automatically blow air at room temperature to bring down temperature to 90 C The panel will then display the following after reaching the safe temperature level and to indicate that the device is now in sleep ...

Page 10: ...1 while the banner is scrolling 3 The display panel B1 will initially indicate 60 which means the device is currently operating at 60Hz of frequency 4 Use buttons C3 and C4 to switch between 50 Hz and 60Hz 5 Press C2 to confirm The system will resume automatically Temperature Setting and Adjustment 1 While the unit is ON and the Hot Air Gun switch set to Reworking press buttons C1 or C2 from the c...

Page 11: ...d value This is normal and should not have any negative impact on reworking Note The temperature range is between 60 C and 480 C Airflow Level Setting and Adjustment 1 While the unit is ON and the Hot Air Gun switch set to Reworking press buttons C3 or C4 from the control panel to increase or decrease the airflow level respectively 2 The display panel B2 will show something like EYYY while air pre...

Page 12: ... by unscrewing the fuse holder Replace only with the same fuse type size and rating Use the table below as reference Keep a spare fuse of the same rating for emergency purpose Location Rating Size Rear Panel 3A 220V 5mm 20mm 5A 110V Spare Parts List Number Name Specification 10094 Hot air gun heating element 30104S Plastic handle of hot air gun S003 Hot air gun complete handle 20932 Hot air gun me...

Page 13: ...oosen the clip securing the heating element to the base of the handpiece and slide out the heating element 7 Insert new heating element and reconnect the thermal sensor wires use heatshrinktubes to avoid shorting of thermal sen or Be careful not to rub Heating Element wire 8 Reconnect the ground wire after replacing the element 9 Assemble the handle again Basic Troubleshooting Guide Problem 1 The ...

Page 14: ... from the digital panel rendering the device unusable Solution Try to press Reset from the panel Note that resetting the device will also reset all previously defined configurations Problem 5 Air Pressure Level is Significantly Low no Matter How High the Airflow Level is Calibrated Case 1 Check the mains voltage AC power source If the voltage level falls significantly low about 1520 lower than the...

Page 15: ...e Operation Issues Solution Try to press the Reset button on the device Note that resetting the device will also reset all previously defined configurations Problem 9 For SS 952 Only Air Pressure Drops When Using the Suction Pen Description The Air pressure drops when using the suction pen and does not recover to its previous height in the air gauge Solution Decrease the air pressure level set air...

Page 16: ... to be accurate but the Group assumes no responsibility for its accuracy or completeness any error in or omission from it or for any use made of it Users of this data sheet should check for themselves the Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted Liability for loss or damage resulting from any reliance on...

Reviews: