Range
Resolution
Error limit: ± (% r count)
40°C~400°C
1°C
±(1%+10)
40°C~1000°C
±2.5%
-40°F~104°F
2°F
±(2%+18)
104°F~752°F
±(1%+18)
752°F~1832°F
±2.5%
Overload protection: 1000V
Temperature sensor: K type (Ni-Cr and Ni- Si) thermocouple
(14) AC v LPF
Range
Resolution
Remark
6V
0.001V
Intercept AC voltage signal higher than 1kHz
60V
0.01V
600V
0.1V
1000V
1V
(15) AC LPF
Range
Resolution
Remark
600A
0.1A
Intercept AC voltage signal higher than 1kHz
2500A
1A
10. Maintenance and Upkeep
1. General maintenance
Warning: to prevent electrical shock, keep the test leads disconnected if opening the housing for battery or fuse maintenance.
a. The clamp meter should be serviced or repaired only by a qualified professional technician.
b. When needed, wipe the outer casing with a clean cloth.
Do not use abrasive materials or solvents.
2. Installation or replacement of battery
A 9V (6LF22) battery provides power for the clamp meter. To install or replace battery:
a. Turn off the clamp meter, and remove test leads from input terminals.
b. Gently place the meter panel face down, and remove battery cover screw. Lift the battery cover off, and install new battery
-paying attention to the indicated polarity.
c. Only use the same type of 9V Alkaline battery. Do no try to fit with another battery type or mains power.
d. After installing battery, replace and secure battery cover and screw.
Important Notice :
This data sheet and its contents (the “Information”) belong to the members of the AVNET group of companies (the “Group”) or are licensed to it. No licence is granted for
the use of it other than for information purposes in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change
without notice and replaces all data sheets previously supplied. The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness,
any error in or omission from it or for any use made of it. Users of this data sheet should check for themselves the Information and the suitability of the products for their purpose and not make
any assumptions based on information included or omitted. Liability for loss or damage resulting from any reliance on the Information or use of it (including liability resulting from negligence or
where the Group was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict the Group’s liability for death or personal injury resulting from its
negligence. TENMA is the registered trademark of Premier Farnell Limited 2019.