D Continuity Test
Range
Resolution
Accuracy
Overload
Protection
400.0
0.1
Approximate 100
1000Vp
Remarks:
l
Buzzer beeps continuously.
l
Open circuit voltage approximate 0.45V.
E. Diode Test
Range Resolution
Overload Protection
Diode 1mV 1000Vp
Remarks:
l
Open circuit voltage approximate 1.48V.
l
Displays approximate forward voltage drop reading
0.5V~0.8V.
F. Capacitance
Resolution
Accuracy
Overload
Protection
Measure at REL mode
(3%+10)
(3%+5)
(4%+5)
1000Vp
G. Frequency & Duty Cycle
Range
Resolution Accuracy
Overload
Protection
10Hz~10MHz
0.1%~99.9% 0.01%
1000Vp
Remarks:
l
10Hz~10MHz Range:
l
0.1%~99.9%:
Reading is only for reference purpose.
Accuracy Specifications (2)
300mV rms input sensitivity 30V rms;
600mV rms input sensitivity 30V rms.
1MHz:
1MHz:
Range
(0.1%+3)
28
Model 72-7740/72-7745: OPERATING MANUAL