background image

5

ZERO BUTTON

HOLD BUTTON

BACKLIGHT BUTTON

ZERO

: base reset button. This function is used with REL and works at the DC function.

Since the clamp head of the meter generates the induced voltage due to earth

magnetic field induction when it does not measure any signal, the base number

exists at DC gear generally and varies from the placement position and direction of

the Meter.

It is necessary to deduct the base number at the time of DC measurement.

Press the 

ZERO

 button under DC function to enter reset mode and deduct the

base number during DC measurement.

Under reset mode, it will display Dn-Df on the main display screen, of which Df is

the DC base number and Dn is the current measured value.

Meanwhile, it will display the “ZERO” symbol at the top left of the display screen,

which indicates it has entered reset mode.

By pressing the 

ZERO

 button again under reset mode, it will update Df again and

display the updated Dn-Df.

To exit the reset function either press and hold the 

ZERO

 button, turn the function

dial, or press 

SELECT

.

Press the 

HOLD

 button under reset mode, it will enter data-hold mode and the

Meter will not update the measurement data. When you exit reset mode, “hold”

state will be cancelled also.

HOLD

: the data hold button works with all functions.

To enter data-hold mode, press the 

HOLD

 button under normal measurement

mode.

The Meter will not update the measurement data and the displayed value will be

locked and remain unchanged.

It will display the “H” symbol at the top left of the display screen, which indicates it

has entered data-hold mode.

If you wish to exit data-hold mode either press 

HOLD

, turn the function dial or

press 

SELECT

.

entered relative value measuring mode.

You can return to normal operation mode by pressing the 

REL

 button again, or

pressing 

SELECT

 for a function switch.

Press the 

HOLD

 button under relative value measuring mode and it will enter data-

hold mode as well and the Meter will not update the measurement data. When you

exit relative value measuring mode, “hold” state will be cancelled also.

Press and hold the       button to turn on the backlight and enter low-light mode, 

which means the backlight is bright enough for basic reading.

Press and hold the       button again to enter the high-light mode, under which the 

backlight is brighter and the contrast is clearer.

Press and hold the       button again to turn off the backlight.

Summary of Contents for 72-3545

Page 1: ...1 200A True RMS Fork Meter Models 72 3545...

Page 2: ...ng AC Voltage Specification 7 Measuring DC Voltage Specification 8 Measuring Resistance Specification 8 Conductivity Testing Specification 8 Diode Measurement Specification 8 Measuring Capacitance Spe...

Page 3: ...ge to the Meter Use extra care when measuring DC voltage of higher than 42V or 30V AC RMS as there may be danger of an electric shock Do not measure voltage or current higher than the allowable input...

Page 4: ...nce capacitance and other parameters are measured SELECT BUTTON SELECT function selection button which works at AC DC ACV DCV and RES CNT DIO CAP functions When the function dial is switched to AC DC...

Page 5: ...nter data hold mode and the Meter will not update the measurement data When you exit reset mode hold state will be cancelled also HOLD the data hold button works with all functions To enter data hold...

Page 6: ...to be measured into the centre position of the probe Impact resistant strength 1m high impact can be borne Max opening dimension of clamp head Diameter of 14 7mm Max dimension of current wire Diamete...

Page 7: ...e Resolution ratio Accuracy Overload protection 200 0A 0 1A 2 5 5 200A The DC base number can be cleaned up by pressing the ZERO button AC VOLTAGE SPECIFICATION Measurement range Resolution ratio Accu...

Page 8: ...circuit voltage is about 1 2V DIODE MEASUREMENT SPECIFICATION Measurement range Resolution ratio Accuracy Overload protection 6 000V 0 001V 0 5V 0 8V 1000V DC 750V AC Open circuit voltage is about 3 3...

Page 9: ...button to switch into the measuring function range of DC current Clear the base number of the measuring range of DC current As the clamp head sensor reacts to terrestrial magnetism and surrounding ma...

Page 10: ...be greater than 750V AC MEASURING DC VOLTAGE Insert the black probe into the COM input and insert the red probe into the V input ready for measurement Set the measuring function range by rotating the...

Page 11: ...ort circuit the meter probe and press the REL button to clear the probe short circuit base number before measurement to eliminate the impact of probe resistance CONDUCTIVITY TESTING Insert the black p...

Page 12: ...lack probe into the COM input and the red probe into the V input ready for measurement Set the measuring function range by rotating the dial so it aims at the capacitance symbol Press SELECT to switch...

Page 13: ...al screen will display such four grades as and The greater the induced voltage the higher the grade displayed MAINTENANCE Warning Remove the test probes before uncapping the lid in order to avoid elec...

Page 14: ...must be treated as Waste Electrical Electronic Equipment WEEE Any WEEE marked products must not be mixed with general household waste but kept separate for the treatment recovery and recycling of the...

Reviews: