Please read these instructions carefully before use and retain for future 

reference.

This instrument is designed and manufactured in compliance with: G84793,  

lEC61010-1, CAT III 600V Pollution Degree 2 and Double Insulation standards.

• 

Check the test leads, probes and case insulation before using. If you find any 

breakage or abnormality, or you consider the device is broken, stop using the 

device immediately.

• 

When using the test probes, keep your fingers behind the finger protection ring.

• 

Do not use the meter with the back cover open.

• 

Select appropriate test range for measurements.

• 

Ensure all inputs are less than the range selected otherwise it may cause electrical 

shock or meter damage.

• 

Do not change the range selector position during voltage or current 

measurements.

• 

Do not apply a voltage over 600V between COM terminal and ground.

• 

Take caution when working voltages are above 60V DC or 30V AC rms.

• 

Do not connect the meter to voltage signals when the range selector is on current, 

resistance, diode or continuity range.

• 

When measuring current, each single measurement should be shorter than 10 

seconds. For current values over 5A, the wait period between each measurement 

must be longer than 15 minutes.

• 

When a measurement has been completed, disconnect the testing probes from 

the circuit under test.

• 

Replace the batteries as soon as the low battery indicator appears on the display.

• 

Remove dead batteries from the meter or if it is not going to be used for a long 

time.

• 

Never mix old and new batteries together, or different types of batteries.

• 

Never dispose of batteries in a fire, or attempt to recharge ordinary batteries.

• 

Before replacing the battery, turn off the meter and disconnect all the test probes.

• 

To prolong battery life turn off the meter after use.

• 

CAT III: Measurement category III is for measurements performed in the building 

installation. Examples are measurements on distribution boards, circuit-breakers, 

and wiring, such as cables, bus-bars, junction boxes, switches and socket-outlets 

in the fixed installation, and equipment for industrial application and some other 

equipment such as stationary motors with permanent connection to the fixed 

installation.

• 

Only use test leads and probes that are in compliance with IEC 61010-031, and 

rated CAT III 600V.

SYMBOL GUIDE

Low battery 

Grounding

Diode

Continuity Buzzer

AC

DC

IMPORTANT SAFETY INFORMATION

Summary of Contents for 72-2600

Page 1: ...1 Model 72 2600 Digital Multimeter ...

Page 2: ... shorter than 10 seconds For current values over 5A the wait period between each measurement must be longer than 15 minutes When a measurement has been completed disconnect the testing probes from the circuit under test Replace the batteries as soon as the low battery indicator appears on the display Remove dead batteries from the meter or if it is not going to be used for a long time Never mix ol...

Page 3: ...cy Input Impedance Overload protection 200mV 10µV 0 05 3 Around 10MΩ 600VAC DC RMS 850V p p 2V 100µV 0 1 3 20V 1mV 0 15 5 200V 10mV 600V 10mV 1 2 3 4 5 AC VOLTAGE Range Resolution Accuracy Input Impedance Overload protection 200mV 10µV 0 8 10 Around 10MΩ 600VAC DC RMS 850V p p 2V 100µV 0 5 10 20V 1mV 0 6 10 200V 10mV 600V 100mV 0 8 15 Displays effective value of sine wave AC voltage frequency rang...

Page 4: ...ent is allowed When 5A use 10 seconds measurement at an interval of more than 15 minutes Measured voltage drop 200mV for full range AC current frequency range 40hz 400hz Display true RMS value waveform coefficient is not more than 5 RESISTANCE Range Resolution Accuracy Overload Protection 200Ω 0 01Ω 0 5 10 600V AC DC RMS 2kΩ 0 1Ω 0 3 3 20kΩ 1Ω 0 3 1 200kΩ 10Ω 2MΩ 100Ω 20MΩ 1kΩ 0 5 1 Open circuit v...

Page 5: ...cuit voltage approx 3 0V OPERATION Rotary Switch Below table indicates the rotary selector switch position functions DC Voltage measurement AC Voltage measurement AC Current measurement DC Current measurement F Capacitance measurement Hz Frequency measurement Diode Test Continuity sounder Resistance measurement Ω A A Hold Button Press to enter or exit data hold mode The Hold mode is applicable to ...

Page 6: ...reduce it step by step until a satisfactory reading is obtained Do not attempt to measure higher than 600V or the meter may be damaged and there may be a risk of electric shock Disconnect from the circuit under test when changing the range If the display only shows 1 it indicates the measured voltage is out of range In this case turn the range selector to a higher range Measuring DC Current Insert...

Page 7: ...leads Inserting the capacitor directly is more stable and suitable for small value of capacitance testing 1 is displayed if the tested capacitor is shorted or exceeds the maximum range For high capacitance measurement it is normal for it to take several seconds to obtain a stable reading When capacitance testing has been completed disconnect the connection between the testing leads and the item un...

Page 8: ...ter CLEANING Frequency measurement Insert the red test lead into the Hz terminal and the black test lead into the COM terminal Set the rotary switch to 20kHz frequency measurement Connect the test leads across the object being measured and the value shows on the display When frequency measurement has been completed disconnect the connection between the testing leads and the circuit under test and ...

Reviews: