Please read this manual before operating the equipment.

Keep manual in accessible place for future reference.

What’s Included

Multimeter 

1 No.

Test Lead 

1 Set.

K Type Temperature Probe  1 No.
User Manual

1. Overview

72-10390A multimeter is a hand-held 3-1/2 digital display digital multimeter with advanced design, multiple entire functions, 

novel  figurations  and  reliable  performance.  This  meter  is  fully  capable  to  measure  voltage  both AC  and  DC,  DC  current, 

resistance, capacitance, inductance, temperature and forward voltage drop of diode, transistor, continuity test and square 

wave output etc. This operating manual covers information on safety and cautions to full fill CE mark standard. Please read the 

relevant information carefully and observe all the warnings

 Warning

:  

To avoid electric shock or personal injury, read the “Safety Information” and “Rules for Safe Operation” 

carefully before using the Meter.

2. Safety Information

This meter complies with the standard IEC/EN 61010-1, 61010-2-033 in pollution degree 2, over voltage category 

 

(CAT III 600V) and double insulation.
CAT. II: Local level, appliance, PORTABLE EQUIPMENT etc., with smaller transient voltage over voltage than CAT. III
CAT. III: Distribution level, fixed installation, with smaller transient over voltage than CAT. IV
Use the meter only as specified in this operating manual, otherwise the protection provided by the meter may be impaired.
1.  Before using the meter inspect the case.  Do not use meter if it is damaged the case (or part of the case) is removed. Look 

for cracks or missing plastic. Pay attention to the insulation around the connections.

2.  Inspect the test leads for damaged insulation or exposed metal. Replace damaged test leads with identical model number or 

electrical specifications before using the meter.

3.  Replace the battery as soon as the battery indicator “

” appears. With a low battery, the meter might produce false readings 

that can lead to electric shock and personal injury.

4. When measurement is on / off against the correct testing position.

5.  Do not apply more that the rated voltage, as marked on the meter in order to avoid possible electric shock or personal injury 

and avoid possible damage to the meter.

6. Do not change the measuring range during the testing as it causes to damage the meter.

7.  When each measurement has been completed, disconnect between the test leads and the circuit under test connection, 

then turn the meter power off and remove the test leads away from the input terminals of the meter. It is a vital for the high 

current measurement.

8. When the meter working at an effective voltage over 60V in DC and 30Vrms in AS, special care should be taken.

9.  When servicing the meter, use only the replacements parts, such as the test leads, with the same model or identical electri-

cal ratings.

10.  Do not use or store the meter in an environment of high temperature and humidity. The performance of the meter may 

deteriorate after dampened.

Summary of Contents for 72-10390A

Page 1: ...www element14 com www farnell com www newark com www cpc co uk TM TM Page 1 V1 0 22 08 18 Palm Size Digital Multimeter 72 10390A User Manual ...

Page 2: ...rating manual otherwise the protection provided by the meter may be impaired 1 Before using the meter inspect the case Do not use meter if it is damaged the case or part of the case is removed Look for cracks or missing plastic Pay attention to the insulation around the connections 2 Inspect the test leads for damaged insulation or exposed metal Replace damaged test leads with identical model numb...

Page 3: ...easurement Operation First check on 9V battery then turn rotary switch to the measuring position If the low battery sign will be displayed on LCD panel Nearly to sign on the meter front panel terminal input which also not exceed the testing voltage and current input value limitation 1 DC or AC Voltage Measurement See Diagram 2 1 Turn rotary switch to V or V voltage measurement 2 Insert the red tes...

Page 4: ...Ω ohm measurement 2 Insert the red test lead into the Ω terminal and the black test lead into the COM terminal Connect the test leads across with the object being measured The measured value shows on the display The LCD displays OL indicating open circuit for the tested resistor or the resistor value is higher than the maximum range of the meter To maintain the resistance measurement accuracy disc...

Page 5: ...The open circuit of diodes is 2 3V Do not input higher than DC 60V and AC 30V voltage to prevent any damage and accident 5 Temperature Measurements see diagram 7 1 Turn rotary switch to C 2 K type point contact temperature probe can only be used in the measurement below 230 C you need to separately buy another temperature probe 3 The LCD displays OL indicating point contact temperature probe which...

Page 6: ...Current Range Resolution Accuracy 2000µA 1µA 1 Reading 2 Digits 20mA 0 01mA 1 Reading 2 Digits 200mA 0 1mA 1 2 Reading 2 Digits 10A 0 01A 2 Reading 5 Digits Overload Protection mA Range F2 fuse Ø6 35 x 31 8mm F 0 5A H 600V CE 10A Range F1 fuse Ø6 35 x 31 8mm F 10A H 600V CE Warning When 5A Continuous measurement is allowed When 5A Continuous measurement less than 10 seconds at an interval more tha...

Page 7: ...Ω Buzzer beep continuously Overload Protection 600V AC or DC 7 Maintenance and Service Warning Make sure the test leads take off the terminal and the circuit as well as power off the meter if want to open the meter cover 1 General Service and Maintenance Periodically wipe the case with a damp cloth and mild detergent Do not use abrasives or solvents Any abnormal on the meter stop use the meter and...

Page 8: ...selves the Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted Liability for loss or damage resulting from any reliance on the Information or use of it including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising is excluded This will not operate to li...