vi
METERING
FRONT PANEL CONTROLS
STATUS INDICATORS
PLATE VOLTAGE SUPPLY
SCREEN SUPPLY
CONSTRUCTION
SIZE
WEIGHT
Full time plate current meter. Second meter selectable for
screen grid current, plate voltage, forward power, and
reflected power (x10). Peak forward power indicated on
full-time LED bargraph display.
TUNE and LOAD control knobs with 6:1 reduction drive.
Rotary band switch and meter switch for screen grid
current, plate voltage, forward or reverse power.
Standby / Operate , QSK / PTT-VOX and Power on/off
rocker switches.
Power on, wait, standby/operate, screen grid over-current,
control grid over-current.
Step-start inrush protected. Approximately 3000 VDC @
no load, approximately 2700 VDC @ full load.
6 amp, 1000 PIV diodes in fullwave bridge circuit. 9 each
220 uF electrolytic filter capacitors. 10 ohm arc
absorption resistor.
360 VDC voltage regulated, current limited.
.125” aluminum plate transformer and RF tank chassis.
.062” aluminum control / airbox chassis and covers.
HWD = 8.5" x 19" x 20"
(21.6 x 48.3 x 50.8 cm)
84 lbs. (38.18 kg)