Temtop S1 User Manual Download Page 17

Elitech Technology, Inc. 

2528 Qume Dr, Ste 2 
San Jose, CA 95131 USA 
Tel: +1 408-898-2866 
Sales: [email protected] 
Website: www.temtopus.com 

Elitech Brasil Ltda  

R. Dona Rosalina, 90 - Igara, Canoas - RS, 
92410-695, Brazil 
Tel: +55 (51)-3939-8634 
Sales: [email protected] 
Website: www.elitechbrasil.com.br 

Elitech (UK) Limited 

Unit 13, Greenwich Centre Business Park 
53 Norman Road, London, SE10 9QF UK 
Tel: +44 (0)208-858-1888 
Sales: [email protected] 
Website: www.elitecheu.com

 V1.0

Summary of Contents for S1

Page 1: ...S1 User Manual ...

Page 2: ...ity may lead to an increase in household air pollutants especially the biological contaminants such as molds bacteria viruses and dust mites cold low humidity may cause nosebleeds skin and respiratory irritations dyspnea staticelectricity andetc AQI Air Quality Index is a quick guide showing how clean or polluted the air is using a range from 0 to 500 where higher index values indicate higher leve...

Page 3: ...may not work properly This product is only used to monitor the health of the indoor environment and cannot be used as a professional measurement tool Do not disassemble the device In the event of a defect please contact your dealer The dealer will contact the Service Centre and can send the device in to be repaired if necessary Children should only use the device under adult supervision Keep packa...

Page 4: ... Work mode PM2 5 AQI level Temperature Humidity level Battery level Charging status Health level display area Built in magnet Vents Air inlet 3 Overview ...

Page 5: ... Power button air outlet USB port Mode button Temperature and humidity detection port Bracket Optional 4 Overview ...

Page 6: ...y S1 Sensor Laser PM sensor Measuring range 0 999 µg m Resolution 0 1 µg m Accuracy 5 µg m 0 50 µg m 10 µg m 50 100 µg m 10 100 500 µg m Measuring range 10 60 C Resolution 0 1 C Accuracy 0 5 C Measuring range 0 99 9 RH Resolution 0 1 RH Accuracy 3 RH 3 5 2 7 0 7 inches 800mAh ...

Page 7: ...de 5min Power saving Mode 30min 14hr Real time mode 7Days Power saving Mode 5V 1A Segment code screen 3 3inches About 110g 10 60 C 0 99 9 1 Whentheproductischarged thetemperaturewillhaveanerrorof 0 5 C anditwillrecoverinabout 10 minutes after full change 2 Whenthetemperaturemeasurementenvironmentsuddenlychanges andthetemperaturedifference is large it takes 3 to 5 minutes Adaptation time ...

Page 8: ...Keep the room area airtight for 10 minutes to obtain more accurate results If battery level shows please charge the detector promptly to avoid effects during use also chargeable when turned off Warning 7 Operation ...

Page 9: ...8 Press 3s to turn ON OFF the S1 monitor Long press 3S 1 On Off ...

Page 10: ...tion and product battery life to provide users with a good experience Real time mode Real time collection of temperature humidity and particulate matter data on the device Note The data is collected about 1 5 seconds for particulate matter and about 5 seconds for temperature and humidity 2 Display A R Mode Button 1 Short press to switch between the work mode 4 different types 2 Long press to switc...

Page 11: ...n willflash3times and then shut down Power display Charging icon USB interface 10 Interval Mode 5min 1 PM2 5 Sensor works every 5 minutes 2 The temperature and humidity are still maintained for 1 minute to refresh Power saving Mode 30min 1 PM2 5 Sensor works every 30 minutes 2 The temperature and humidity are still maintained for 1 minute to refresh S1 monitoring function 30 ...

Page 12: ...11 Air Quality Parameter for Reference Pollutant PM2 5 µg m AQI Status GOOD 0 12 0 50 FAIR 12 1 55 4 51 150 POOR 55 4 150 Refers to EPA Standards ...

Page 13: ...12 Place The Scene Directly place Bracket placement Magnetic placement ...

Page 14: ...ence the PM2 5 concentrations and give differences in the readings Q Why is the test result abnormal or below normal A Please check whether the air inlet or outlet has been covered or fuid is in Gently shake the detector during detection to increase the interaction with surrounding air The sensor may be not recovered Please place the detector outdoors for ventilation Q Why is data reading unstable ...

Page 15: ...14 What s Included Detector x 1 USB Cable x 1 User Manual x 1 Bracket or accessories set x1 Optional ...

Page 16: ...Malfunction or damages caused by artificial damage or modification Other deliberate damages Temtop warrants the included detector for 1 year from the date of original purchase The item can be exchanged or returned within 30 days if the defect is not caused by artificial damage Detector Accessories Complete Package Proof of Purchase Gift if any Return Exchange Repair ...

Page 17: ...s com Elitech Brasil Ltda R Dona Rosalina 90 Igara Canoas RS 92410 695 Brazil Tel 55 51 3939 8634 Sales brasil e elitech com Website www elitechbrasil com br Elitech UK Limited Unit 13 Greenwich Centre Business Park 53 Norman Road London SE10 9QF UK Tel 44 0 208 858 1888 Sales sales elitech uk com Website www elitecheu com V1 0 ...

Reviews: