11
A180037
Fig. 26
−
Screws Holding Support Plate
9. Remove the two outer screws that attach the blower support
plate to left evaporator coil support. (See Fig. 27) This will
completely release the blower assembly from the unit.
A180038
Fig. 27
−
Two Outer Screws
PERSONAL INJURY HAZARD
Failure to follow this caution may result in personal
injury.
After removing the final screw from Step 9., the blower
assembly will be completely disconnected from the unit.
Be ready to lower the blower assembly.
CAUTION
!
G. FMC4Z & FMU4Z
−
Servicing the Fan Motor
1. After removing the blower housing from the unit, remove
grounding bracket from motor
−
mount assembly by remov-
ing the two screws. (See Fig. 28 & 29)
A180045
Fig. 28
−
Screws Holding the Bracket
A180046
Fig. 29
−
Bend the Holding Bracket
2. At this point, the clamp brackets will be loose and can be
removed. (See Fig. 30)
A180047
Fig. 30
−
Remove Clamp Brackets