background image

46

441 01 2101 05

Specifications are subject to change without notice.

a. Inducer Prepurge Period (see Figure 55 schematic

diagram)

(1.) Low heat (W/W1) the inducer motor IDM comes

up to high

speed, the low

heat pressure switch

LPS closes. After the low

heat pressure switch

closes the furnace control CPU will begin a

15

second prepurge period, and continue to run

the inducer motor IDM at high

speed.

(2.) High Heat (W/W1+W2) the inducer motor IDM

comes up to high speed and the high

heat

pressure switch relay HPSR is de

energized to

close the NC contact. When sufficient pressure

is available, the high

heat pressure switch HPS

closes, and the high

heat gas valve solenoid

GV

HI is energized. After LPS closes, 24VAC

power is supplied for a field

installed humidifier

at the HUM 24VAC terminal and the furnace

control CPU begins a 15

second prepurge

period. If the high

heat pressure switch HPS fails

to close and the low

heat pressure switch LPS

closes, the furnace will operate at low

heat gas

flow rate until the high

heat pressure switch

closes for a maximum of 2 minutes after ignition.

If HPS doesn’t close after 2 minutes from LPS

closing, GV is turned off and heat off delay is

completed. Then a new cycle will begin if a call

for heat remains.

b.

Igniter Warm

Up

At the end of the prepurge period,

the (Hot Surface Igniter) HSI is energized for a

17

second igniter warm

up period.

c.

Trial

for

Ignition  Sequence

When the igniter

warm

up period is completed the main gas valve relay

contacts GVR close to energize the gas valve solenoid

GV

M, the gas valve opens. The gas valve solenoid

GV

M permits gas flow to the burners where it is

ignited by the HSI. 5 sec after the GVR closes, a 2

sec

flame proving period begins. The HSI igniter will

remain energized until the flame is sensed or until the

2

sec flame proving period begins. If the furnace

control CPU operates in high

heat operation, the

high

heat gas valve solenoid GV

HI is also

energized.

d.

Flame

Proving

When the burner flame is proved at

the flame

proving sensor electrode FSE, the inducer

motor IDM switches to low

speed unless running at

high

heat, and the furnace control CPU begins the

blower

ON delay period and continues to hold the gas

valve GV

M open. If the burner flame is not proved

within two seconds, the control CPU will close the gas

valve GV

M, and the control CPU will repeat the

ignition sequence for up to three more

Trials

For

Ignition before going to Ignition

 Lockout.

Lockout will be reset automatically after three hours,

or by momentarily interrupting 115 vac power to the

furnace, or by interrupting 24 vac power at 24VAC or

COM to the furnace control CPU (not at W/W1, G, R,

etc.). If flame is proved when flame should not be

present, the furnace control CPU will lock out of

Gas

Heating mode and operate the inducer motor

IDM on high speed until flame is no longer proved.

e.

Blower On Delay

If the burner flame is proven, the

blower on delay for low

heat and high

heat are as

follows: 

Low

Heat

45 seconds after the gas valve

GV

M is energized the blower motor (BLWM) is

energized at LO HEAT speed. 

High

Heat

25 seconds after the gas valve GV

M is

energized the BLWM is energized at HI HEAT speed.

Simultaneously, the electronic air cleaner (EAC 1

AMP) terminal is energized and remains energized as

long as the BLWM is energized.

f.

Switching from Low

to High

Heat

If the furnace

control CPU switches from low

heat to high

heat, the

furnace control CPU will switch the inducer motor IDM

speed from low to high. The high

heat pressure switch

relay HPSR is de

energized to close the NC contact.

When sufficient pressure is available the high

heat

pressure switch HPS closes, and the high

heat gas

valve solenoid GV

HI is energized. The blower motor

BLWM will switch to HI HEAT speed 5 seconds after

the furnace control CPU switches from low

heat to

high

heat.

g.

Switching from High

 to Low

Heat

The furnace

control CPU will not switch from high

heat to low

heat

while the thermostat R

to

W circuit is closed when

using a single stage thermostat.

h.

Heat

Off Delay

When the thermostat is satisfied, the

R to W circuit is opened, de

energizing the gas valve

GV

M, stopping gas flow to the burners, and

de

energizing the humidifier terminal HUM 24VAC.

The inducer motor IDM will remain energized for a

5

second post

purge period then turn off,  also

turning off HUM for 115V humidifier. The blower motor

BLWM and air cleaner terminal EAC 1 AMP will remain

energized for 90, 120, 150, or 180 seconds

(depending on selection at heat

off delay switches).

The furnace control CPU is factory

set for a

120

second heat

off delay.

2.

Two

Stage Thermostat and Two

Stage Heating

(See Figure 31 for thermostat connections)

NOTE

:  In this mode the TT switch (SW1

1) must be ON to

select the two

stage thermostat mode in response to closing

the thermostat R

to

W1 circuit. Closing the thermostat

R

to

W1

and

W2 circuits always causes high

heat

operation, regardless of the setting of the thermostat type.
The wall thermostat “calls for heat”, closing the R

to

W1

circuit for low

heat or closing the R

to

W1 and

W2 circuits

for high

heat. The furnace control performs a self

check,

verifies the low

heat and high

heat pressure switch contacts

LPS and HPS are open, and starts the inducer motor IDM in

high

speed.

The start up and shut down functions and delays described in

item 1. above apply to the two

stage heating mode as well,

except for switching from low

 to high

heat and vice versa.

a.

Switching from Low

 to High

Heat

If the

thermostat R

to

 W1 circuit is closed and the

R

to

W2 circuit closes, the furnace control CPU will

switch the inducer motor IDM speed from low to high.

The high

heat pressure switch relay HPSR is

de

energized to close the NC contact. When sufficient

pressure is available the high

heat pressure switch

HPS closes, and the high

heat gas valve solenoid

GV

HI is energized. The blower motor BLWM will

switch to HI HEAT speed five seconds after the

R

to

W2 circuit closes.

b.

Switching from High

 to Low

Heat

If the

thermostat R

to

W2 circuit opens, and the R

to

W1

circuit remains closed, the furnace control CPU will

switch the inducer motor IDM speed from high to low.

The high

heat pressure switch relay HPSR is

energized to open the NC contact and de

energize

the high

heat gas valve solenoid GV

HI.  When the

inducer motor IDM reduces pressure sufficiently, the

high

heat pressure switch HPS will open. The gas

valve solenoid GV

M will remain energized as long as

the low

heat pressure switch LPS remains closed.

The blower motor BLWM will switch to LO HEAT speed

5 seconds after the R

to

W2 circuit opens.

3.  

Cooling Mode

The thermostat “calls for cooling.”

a.

Single

Speed Cooling

 

(See Figure 23 for thermostat connections) 

The thermostat closes the R

to

G

and

Y circuits.

The R

to

Y circuit starts the outdoor unit, and the

furnace control R

to

G

and

Y/Y2 circuits start the

Summary of Contents for F8MTL

Page 1: ...alert to the potential for personal injury TABLE OF CONTENTS SAFETY CONSIDERATIONS 3 INTRODUCTION 4 CODES AND STANDARDS 4 STEP 1 SAFETY 4 STEP 2 GENERAL INSTALLATION 4 STEP 3 COMBUSTION AND VENTILATION AIR 5 STEP 4 DUCT SYSTEMS 5 STEP 5 ACOUSTICAL LINING AND FIBROUS GLASS DUCT 5 STEP 6 GAS PIPING AND GAS PIPE PRESSURE TESTING 5 STEP 7 ELECTRICAL CONNECTIONS 5 STEP 8 VENTING 5 ELECTROSTATIC DISCHAR...

Page 2: ...ctangle d For airflow requirements above 1800 CFM see Air Delivery table in Product Data literature for specific use of single side inlets The use of both side inlets a combination of 1 side and the bottom or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM Table 1 Dimensions FURNACE SIZE A B C D VENT SHIP CABINET WIDTH IN mm OUTLET WIDTH IN mm TOP A...

Page 3: ...ght suggestions which will result in enhanced installation reliability or operation product and property damage NOTE is used to highlight suggestions which will result in enhanced installation reliability or operation 1 Use only with type of gas approved for this furnace Refer to the furnace rating plate 2 Install this furnace only in a location and position as specified in the Location section of...

Page 4: ...uch as when used with a night setback thermostat Return air temperature must not exceed 80 F 27 C db Failure to follow these return air temperature limits may affect reliability of heat exchangers motors and controls SeeFigure 3 For accessory installation details refer to the applicable instruction literature NOTE Remove all shipping brackets and materials before operating the furnace Figure 2 Cle...

Page 5: ...ungrounded objects etc 4 If you touch ungrounded objects and recharge your body with static electricity firmly touch a clean unpainted metal surface of the furnace again before touching control or wires 5 Use this procedure for installed and uninstalled ungrounded furnaces 6 Before removing a new control from its container discharge your body s electrostatic charge to ground to protect the control...

Page 6: ...ents salts air fresheners and other household products Do not install furnace in a corrosive or contaminated atmosphere Make sure all combustion and circulating air requirements are met in addition to all local codes and ordinances WARNING If air is exposed to the following substances it should not be used for combustion air and outdoor air may be required for combustion Permanent wave solutions C...

Page 7: ...ipped with means to prevent operation of either unit unless the damper is in the full heat or full cool position AIR FOR COMBUSTION AND VENTILATION Provisions for adequate combustion ventilation and dilution air must be provided in accordance with U S installations Section 9 3 of the NFPA 54 A ANSI Z223 1 2012 Air for Combustion and Ventilation and applicable provisions of the local building codes...

Page 8: ...gure 7 Air for Combustion Ventilation and Dilution for Outdoors 1 SQ IN PER 4000 BTUH DUCTS TO OUTDOORS 1 SQ IN PER 4000 BTUH C IRCULA TING AIR DUCTS VENT THROUGH ROOF D B A C E 1 SQ IN PER 4000 BTUH DUCT TO OUTDOORS CIRCULATING AIR DUCTS 1 SQ IN PER 2000 BTUH 1 SQ IN PER 2000 BTUH DUCTS TO OUTDOORS 12 MAX 12 MAX 12 MAX 12 MAX 12 MAX OUTDOORS 1 SQ IN PER 4000 BTUH F G CLEARANCE IN FRONT OF COMB US...

Page 9: ...04002 2 For fan assisted appliances such as this furnace Volume Fan 15ft3 ACH I fan 1000 Btu hr A04003 If Iother combined input of all other than fan assisted appliances in Btuh hr Ifan combined input of all fan assisted appliances in Btuh hr ACH air changes per hour ACH shall not exceed 0 60 The following requirements apply to the Standard Method and to the Known Air Infiltration Rate Method 1 Ad...

Page 10: ...s may be used See Figure 10 Install field supplied 5 16 x 1 1 2 in 8 x 38 mm max corrosion resistant machine bolts washers and nuts NOTE Bottom closure must be used when leveling legs are used It may be necessary to remove and reinstall bottom closure panel to install leveling legs To remove bottom closure panel see item 1 in Bottom Return Air Inlet section in Step 1 above To install leveling legs...

Page 11: ...urnace on its back or hang furnace with control compartment facing downward Safety control operation will be adversely affected Never connect return air ducts to the back of the furnace WARNING Suspended Furnace Support The furnace may be supported under each end with threaded rod angle iron or metal plumber s strap as shown See Figure 15 and Figure 16 Secure angle iron to bottom of furnace as sho...

Page 12: ...11 16 322 21 5 8 549 13 5 16 338 22 1 4 565 Downflow Applications on Noncombustible Flooring subbase not required 12 9 16 319 19 483 13 3 16 335 19 5 8 498 Downflow Applications on Combustible Flooring subbase required 11 13 16 284 19 483 13 7 16 341 20 5 8 600 Downflow Applications on Combustible Flooring with Coil END4X ENW4X or Coil Casing NAEA subbase not required 12 5 16 319 19 483 13 5 16 33...

Page 13: ...RON OR UNI STRUT MAY BE USED 2 HEX NUTS 2 WASHERS 2 LOCK WASHERS REQ PER ROD 8 203mm MIN FOR DOOR REMOVAL OUTER DOOR ASSEMBLY A10130 Figure 16 Horizontal Suspension with Straps METHOD 2 USE 4 8 x 3 4 19 mm SHEET METAL SCREWS FOR EACH STRAP THE STRAPS SHOULD BE VERTICAL AGAINST THE FURNACE SIDES AND NOT PULL AWAY FROM THE FURNACE SIDES METHOD 1 FOLD ALL STRAPS UNDER FURNACE AND SECURE WTH 4 8 x 3 4...

Page 14: ...rn air shall also be handled by duct s sealed to the furnace casing and terminating outside the space containing the furnace Secure ductwork with proper fasteners for type of ductwork used Seal supply and return duct connections to furnace with code approved tape or duct sealer NOTE Flexible connections should be used between ductwork and furnace to prevent transmission of vibration Ductwork passi...

Page 15: ...flange may be bent past 90 to allow the evaporator coil to hang on the flange temporarily while the remaining attachment and sealing of the coil are performed Downflow Furnaces Connect supply air duct to supply air outlet on furnace Bend flange inward past 90 with wide duct pliers See Figure 14 The supply air duct must be connected to ONLY the furnace supply outlet or air conditioning coil casing ...

Page 16: ... remain capped until gas supply line is permanently installed to protect the valve from moisture and debris Also install a sediment trap in the gas supply piping at the inlet to the gas valve WARNING Figure 18 Upflow Return Air Configurations and Restrictions 5 TONS AND GREATER 2000 CFM AND GREATER AT 6 ESP HI COOLING SPEED Figure 19 Downflow Return Air Configurations and Restrictions 5 TONS AND G...

Page 17: ...sachusetts Refer to Table 6 for recommended gas pipe sizing Risers must be used to connect to furnace and to meter Support all gas piping with appropriate straps hangers etc Use a minimum of 1 hanger every 6 ft 1 8 M Joint compound pipe dope should be applied sparingly and only to male threads of joints Pipe dope must be resistant to the action of propane gas FIRE OR EXPLOSION HAZARD Failure to fo...

Page 18: ...de purge lines and check for leakage at furnace prior to operating furnace If pressure exceeds 0 5 psig 14 In W C gas supply pipe must be disconnected from furnace and capped before and during supply pipe pressure test If test pressure is equal to or less than 0 5 psig 14 In W C turn off electric shutoff switch located on furnace gas control valve and accessible manual equipment shutoff valve befo...

Page 19: ...R CKT BKR AMPS MINIMUM WIRE GAUGE MAX MIN 0451412 115 60 1 127 104 7 1 9 67 38 11 5 15 14 0701412 115 60 1 127 104 7 3 9 90 37 11 2 15 14 0901714 115 60 1 127 104 8 2 10 84 34 10 3 15 14 1102122 115 60 1 127 104 13 7 17 60 32 9 7 20 12 Permissible limits of the voltage range at which the unit operates satisfactorily Unit ampacity 125 of largest operating component s full load amps plus 100 of all ...

Page 20: ...ox to furnace casing with screws removed in Step 4 11 Secure field ground wire to J Box green ground screw 12 Complete electrical box wiring and installation Connect line voltage leads as shown in Figure 23 Use best practices NEC in U S for wire bushings strain relief etc 13 Reinstall cover to J Box Do not pinch wires between cover and bracket POWER CORD INSTALLATION IN FURNACE J BOX NOTE Power co...

Page 21: ...out notice Figure 26 Two Stage Furnace with Single Speed Air Conditioner Figure 27 Two Stage Furnace with Two Stage Air Conditioner Figure 28 Two Stage Furnace with Single Stage Heat Pump Dual Fuel Figure 29 Two Stage Furnace with Two Stage Heat Pump Dual Fuel ...

Page 22: ...wer motor operation See Figure 33 2 Humidifier HUM 24VAC and HUM a HUM 24VAC Connect an accessory 24 VAC 0 5 amp maximum humidifier if used to the in male quick connect HUM 24VAC terminal and C screw terminal on the control board thermostat strip The HUM 24VAC terminal is energized when there is a call for heat W and the pressure switch PRS closes See Figure 33 and Figure 55 b HUM connect an acces...

Page 23: ...ECTOR TRANSFORMER 24VAC CONNECTIONS P2 HOT SURFACE IGNITOR HSI INDUCER MOTOR CONNECTOR 115 VAC L1 LINE VOLTAGE CONNECTION EAC TERMINAL 115 VAC 1 0 AMP MAX SPARE2 SPARE1 COM BLUE 115 VAC L2 NEUTRAL CONNECTIONS 24 V THERMOSTAT TERMINALS HUMIDIFIER TERMINAL 24 VAC 0 5 AMP MAX 3 AMP FUSE LED OPERATION DIAGNOSTIC LIGHT 24VAC RED BLOWER SPEED SELECTION TERMINALS HUM XFMR HUMIDIFIER TERMINAL 115 VAC HUM ...

Page 24: ...the venting system These furnaces are approved for common venting and multi story venting with other fan assisted or draft hood equipped appliances in accordance with the NFCG local building codes and furnace and vent manufacturers instructions The following information and warning must be considered in addition to the requirements defined in the NFGC CARBON MONOXIDE POISONING HAZARD Failure to fo...

Page 25: ...25 441 01 2101 05 Specifications are subject to change without notice Figure 34 Chimney Inspection Chart A10133 ...

Page 26: ...ble size in the tables the chimney should be rebuilt or relined to conform to the requirements of the equipment being installed and the authority having jurisdiction A chimney without a clay tile liner which is otherwise in good condition shall be rebuilt to conform to ANSI NFPA 211 or be lined with a UL listed metal liner or UL listed Type B vent Relining with a listed metal liner or Type B vent ...

Page 27: ...w vent gas temperatures causing condensation and corrosion in the furnace and or venting system Derating is permitted only for altitudes above 2000 ft 3 Adjust the air temperature rise to the midpoint of the rise range or slightly above Low air temperature rise can cause low vent gas temperature and potential for condensation problems 4 Set the thermostat heat anticipator or cycle rate to reduce s...

Page 28: ... figures A03210 Figure 38 Downflow Application Vent Elbow Up SEE NOTES 1 2 4 5 7 8 9 on the page following these figures A03211 Figure 39 Downflow Application Vent Elbow Left then Up SEE NOTES 1 2 4 5 6 7 8 9 10 on the page following these figures A03207 Figure 40 Downflow Application Vent Elbow Up then Right SEE NOTES 1 2 3 4 5 7 8 9 on the page following these figures A03212 ...

Page 29: ...Left Application Vent Elbow Right SEE NOTES 1 2 4 5 7 8 9 on the page following these figures A03216 Figure 46 Horizontal Right Application Vent Elbow Left then Up SEE NOTES 1 2 4 5 7 8 9 on the page following these figures A03219 Figure 47 Horizontal Right Application Vent Elbow Left SEE NOTES 1 2 4 5 7 8 9 A02068 Venting Notes for Figure 35 Figure 47 1 For common vent vent connector sizing and v...

Page 30: ...ired re install screws The factory supplied vent elbow does NOT count as part of the number of vent connector elbows The vent connector can exit the furnace through one of 5 locations on the casing 1 Attach the single wall vent connector to the furnace vent elbow and fasten the vent connector to the vent elbow with at least two field supplied corrosion resistant sheet metal screws located 180 apar...

Page 31: ...ses and High Heat operation when R to W W1 and W2 close SW2 2 Heat OFF delay OFF Control heat OFF delay time Used in conjunction with SW1 3 See Table 14 SW3 3 Heat OFF delay ON Control heat OFF delay time Used in conjunction with SW1 2 See Table 14 Table 11 Two Stage Furnace Blower OFF Delay Setup Switch DESIRED HEATING MODE BLOWER OFF DELAY SEC SETUP SWITCH SW1 2 SETUP SWITCH SW1 3 90 OFF OFF 120...

Page 32: ... For installations above 2000 ft 610 M multiply the input on the rating plate by the derate multiplier in Table 11 for the correct input rate 2 Determine the correct orifice and manifold pressure adjustment All models in all positions except Low NOx models in downflow and horizontal positions use Table 15 22 000 BTUH per burner Low NOx models in downflow or horizontal positions MUST use Table 16 2...

Page 33: ...revolution and note reading The 2 or 5 cubic feet dial provides a more accurate measurement of gas flow Figure 49 Orifice Hole BURNER ORIFICE A93059 d Refer to Table 12 for cubic ft of gas per hr e Multiply gas rate cu ft hr by heating value Btuh cu ft to obtain input If clocked rate does not match required input from Step 1 increase manifold pressure to increase input or decrease manifold pressur...

Page 34: ... and remove thermostat jumpers e To change motor speed selection for low heat remove blower motor lead from control LO HEAT terminal See Figure 33 Select desired blower motor speed lead from one of the other terminals and relocate it to the LO HEAT terminal See Table 13 for lead color identification Reconnect original lead to SPARE terminal f Repeat steps a through e FURNACE OVERHEATING HAZARD Fai...

Page 35: ...d from one of the other terminals and relocate it to the HI HEAT terminal DO NOT use the low heat tap that was already set See Table 13 for lead color identification Reconnect original lead to SPARE terminal e Repeat steps a thru d f When correct high heat input rate and temperature rise is achieved turn gas valve ON OFF switch to OFF g Remove Blower Access Door h Remove manometer or similar devic...

Page 36: ...ace and set room thermostat above room temperature d After normal start up allow furnace to operate for 2 minutes then block vent elbow in furnace 80 of vent area with a piece of flat sheet metal e Furnace should cycle off within 2 minutes If gas does not shut off within 2 minutes determine reason draft safeguard switch did not function properly and correct condition f Remove blockage from furnace...

Page 37: ...37 441 01 2101 05 Specifications are subject to change without notice Table 15 Orifice Size and Manifold Pressures in w c for Gas Input Rate A10184 ...

Page 38: ...38 441 01 2101 05 Specifications are subject to change without notice Table 15 Orifice Size and Manifold Pressures in w c for Gas Input Rate cont A10184A ...

Page 39: ...39 441 01 2101 05 Specifications are subject to change without notice Table 16 Orifice Size and Manifold Pressures in w c for Gas Input Rate A10185 ...

Page 40: ...omponents or materials i e oil refrigerant control board etc before unit final disposal CAUTION ELECTRICAL SHOCK FIRE OR EXPLOSION HAZARD Failure to follow this warning could result in personal injury or death Before installing modifying or servicing system main electrical disconnect switch must be in the OFF position and install a lockout tag There may be more than one disconnect switch Lock out ...

Page 41: ...st as shown on the SERVICE label located on the of blower access door Step 2 Care and Maintenance For continuing high performance and to minimize possible furnace failure periodic maintenance must be performed on this furnace Consult your local dealer about proper frequency of maintenance and the availability of a maintenance contract FIRE OR EXPLOSION HAZARD Failure to follow this warning could r...

Page 42: ...42 441 01 2101 05 Specifications are subject to change without notice Figure 51 Service Label ...

Page 43: ...r door 3 For downflow or horizontal furnaces having vent pipes within the furnace that pass in front of the blower access door a Disconnect vent connector from furnace vent elbow b Disconnect and remove short piece of vent pipe from within furnace 4 Remove two 2 screws from blower access door and remove blower access door 5 All factory wires can be left connected but field thermostat connections m...

Page 44: ...ombustion air incorrect size or damaged manifold orifice s improper gas or a restricted heat exchanger Action must be taken to correct the problem If it becomes necessary to clean the heat exchangers because of dust or corrosion proceed as follows 1 Turn OFF gas and electrical power to furnace 2 Remove outer access door 3 Disconnect vent connector from furnace vent elbow 4 For downflow or horizont...

Page 45: ...st for gas leaks with an open flame Use a commercially available soap solution made specifically for the detection of leaks to check all connections WARNING Step 3 Sequence of Operation NOTE Furnace control must be grounded for proper operation or control will lockout Control is grounded through green wire connected to gas valve and burner bracket screw Using the schematic diagram in Figure 55 fol...

Page 46: ...om Low to High Heat If the furnace control CPU switches from low heat to high heat the furnace control CPU will switch the inducer motor IDM speed from low to high The high heat pressure switch relay HPSR is de energized to close the NC contact When sufficient pressure is available the high heat pressure switch HPS closes and the high heat gas valve solenoid GV HI is energized The blower motor BLW...

Page 47: ...lower motor BLWM will operate on continuous blower speed LO HEAT speed Terminal EAC 1 AMP is energized as long as the blower motor BLWM is energized During a call for heat the blower BLWM will stop during igniter warm up 17 seconds ignition 7 seconds and blower ON delay 45 seconds in low heat and 25 seconds in high heat allowing the furnace heat exchangers to heat up more quickly then restarts at ...

Page 48: ...48 441 01 2101 05 Specifications are subject to change without notice Figure 55 Wiring Diagram 337797 201 Rev B ...

Page 49: ...49 441 01 2101 05 Specifications are subject to change without notice Figure 56 Troubleshooting Guide Two Speed ...

Page 50: ...50 441 01 2101 05 Specifications are subject to change without notice NOTE NUMBER IN UPPER LEFT HAND CORNER REPRESENTS FLASH CODE ...

Page 51: ...lower Motor S Single stage T Two stage TYPE N Standard L Low Nox FEATURE 045 45 000 BTU hr 070 70 000 BTU hr 090 90 000 BTU hr 110 110 000 BTU hr HEAT INPUT 14 143 16 17 171 2 21 21 24 241 2 CABINET WIDTH 08 800 CFM 12 1200 CFM 14 1400 CFM 16 1600 CFM 20 2000 CFM 22 2200 CFM COOLING AIRFLOW SALES MAJOR REVISION DIGIT ENGINEERING MINOR REVISION DIGIT TO OBTAIN INFORMATION ON PARTS Consult your inst...

Page 52: ...52 Specifications are subject to change without notice 441 01 2101 01 Copyright 2016 International Comfort Products Lewisburg TN 37091 USA ...

Reviews: