Tempstar DFC4A3 Owner'S Manual Download Page 10

OWNER'S MANUAL                      Duct Free Split System - High Wall: DFS4(A/H), DFC4(A/H)3, DFF4(A/H)H

10                                                                                                                                                 421 02 9301 00

Table 1—Periodic Maintenance

INDOOR UNIT

EVERY MONTH

EVERY 6 MONTHS

EVERY YEAR

Clean Air Filter* 
Change Remote Control Batteries

OUTDOOR UNIT

EVERY MONTH

EVERY 6 MONTHS

EVERY YEAR

Clean Outdoor Coil from Outside
Clean Outdoor Coil from Inside†
Blow Air Over Electric Parts†
Check Electric Connection Tightening†
Clean Fan Wheel†
Check Fan Tightening†
Clean Drain Pans†

* Increase frequency in dusty zones.

Maintenance to be carried out by qualified service personnel. Refer to the Installation Manual

Table 2—Troubleshooting

PROBLEM

POSSIBLE CAUSE

SOLUTION

Unit/System Does Not Work

The circuit breaker has tripped or a fuse 
has blown.

Power failure.

Diagnostic lights illuminate.

*

Voltage is too low.

Reset the circuit breaker or replace the fuse with 

the specified replacement fuse.

Restart operation when the power is restored.

Call your service representative.

Call your service representative.

Cooling is Not Working 
Properly

The filter is blocked with dust.

Temperature is not set properly.

A window or door is open.

The outdoor unit is obstructed.

The fan speed is too low.

The operation mode is in Fan instead of 
Cool.

Clean the air filter.

Check the temperature and reset if necessary.

Close the window or door.

Remove the obstruction.

Change the fan speed selection.

Change the operating mode to Cool or reset the 

unit.

Heating is Not Working 
Properly

The filter is blocked with dust.

Temperature is set too low.

A window or door is open.

The outdoor unit is obstructed.

Clean the air filter.

Check the temperature and reset if necessary.

Close the window or door.

Remove the obstruction.

Unit Stops During Operation

The Off timer is not operating correctly.

Diagnostic lights illuminate.

*

Restart the operating mode.

Call your service representative.

* Diagnostic lights are a combination of lights that will illuminate in the display area on the unit.  They are a combination of the lights you see during normal

operation.

International Comfort Products, LLC

Lewisburg, TN 37091

Summary of Contents for DFC4A3

Page 1: ...mation Manual carefully before installing and using this appliance and keep this manual for future reference For your convenience please record the model and serial numbers of your new equipment in the spaces provided This information along with the installation data and dealer contact information will be helpful should your system require maintenance or service UNIT INFORMATION Model ____________...

Page 2: ...authorized kits or accessories when modifying this product WARNING GENERAL The high wall fan coil unit provides quiet maximum comfort In addition to cooling and or heating the high wall fan coil unit matched with an outdoor condensing unit will filter and dehumidify the air in the room to provide maximum comfort IMPORTANT The high wall fan coil unit should be installed by authorized personnel only...

Page 3: ...ctive cable Service valve 1 3 4 5 6 7 8 9 11 12 13 2 INDOOR UNIT OUTDOOR UNIT Remote controller holder 10 10 Indoor Outdoor Unit 1 2 4 5 6 3 8 7 9 10 11 12 13 14 1 2 4 5 6 3 8 7 9 10 11 12 13 14 MODE FAN SPEED TEMP A IR DIRECTIO N SWING LE D SLE EP TURBO CLOCK TIM ER CANCEL RESE T F C AUTO C OOL DRY HEAT FAN SET TEMP CLOCK TIMER ON TIMER OFF SPEED AUTO LOW MED HIGH ON OFF MODE Button ON OFF Button...

Page 4: ... The actual shape of your air conditioner may be slightly different but the operation instructions are the same Remote Control Display A U T OC O O L D R Y H E A T F A N S E T T E M P CLOCK TIMER ON TIMER OFF SPEED AUTO LOW MED HIGH Clock Display Timer Display Lock Display Sleep Display Fan Speed Indicator Transmission Indicator Mode Display ON OFF Indicator Temperature Setting 1 TRANSMISSION Indi...

Page 5: ...tment 3 Replace battery compartment cover NOTE 1 When replacing batteries do not use old batteries or a different type battery This may cause the remote control to malfunction 2 If the remote is not going to be used for several weeks remove the batteries Otherwise battery leakage may damage the remotecontroller 3 The average battery life under normal use is about 6 months 4 Replace the batteries w...

Page 6: ... decrease temperature set point buttons until the desired temperature appears on screen 5 Select the desired fan speed by pressing the FAN SPEED button to select desired fan speed NOTE If unit is operating in Dry mode the auto fan speed will be displayed 6 Set the airflow direction When the unit is turned on the louvers default to the cooling or heating position The user can adjust louver position...

Page 7: ...ling or heating When in heating there might be situations where the fan will slow down or shut off to prevent cold blow Selecting the Horizontal Direction Louver Position In order to optimize comfort the horizontal louvers can operate in a preset range as shown below Cooling Heating The horizontal louvers can be adjusted using the remote control The horizontal louvers can be either stationary or m...

Page 8: ... will be cancelled if any button on the remote control is pressed Heat Mode Same as cooling mode but set points will be lowered by 1 8 F 1 C Turbo Mode This function is available in COOL mode on 9k and 12k cooling only units Use the TURBO mode to cool the room rapidly Press the TURBO button An audible beep will be heard The fan will run on high speed The TURBO mode terminates automatically 20 minu...

Page 9: ...UIPMENT DAMAGE HAZARD Failure to follow this caution may result in equipment damage When cleaning the front panel do not use water hotter than 105 F 40 56 C and do not pour water onto the fan coil Do not use abrasive or petroleum based cleaners as they may damage the front panel CAUTION Indoor Unit Front Panel To clean the front panel on the indoor unit wipe the outside with a soft dry cloth If ne...

Page 10: ...ur service representative Call your service representative Cooling is Not Working Properly The filter is blocked with dust Temperature is not set properly A window or door is open The outdoor unit is obstructed The fan speed is too low The operation mode is in Fan instead of Cool Clean the air filter Check the temperature and reset if necessary Close the window or door Remove the obstruction Chang...

Reviews: