TempSen TPLR-120 Series User Manual Download Page 2

TOUCH SCREEN PAPERLESS RECORDER

 

            

www.tempsendevices.net 

Page 2  

 

  

  

  

    

WHEN YOU RECEIVE THIS INSTRUMENT... 

 

Thank you for purchasing the 

TEMPSEN DEVICES, TPLR-120 MULTI COLOR TOUCH SCREEN PAPERLESS 

RECORDER. 

Please read the instruction manual carefully and use the instrument correctly. 

 

 

TEMPSEN DEVICES

 assumes no liability to any party for any loss or damage, direct or indirect, caused 

by the use or any unpredictable defect of the product. 
Cleaning of the front panel should be limited to wiping lightly with a dry cloth. 

 

 

       Check that all of the following items are present. 

 

 

Paperless Recorder  Range 

 

Input  Type  

 

Output  indication 

 

Communication  interface 

 

A pair of mounting bracket 

 

Operating Voltage  

 

Serial link cable between Recorder& PC Output. 

 

PEN DRIVE use after antivirus scanning  

 

      INSTALLATION 
 

         Installation Location 

Install the control panel in a location that meets the following criteria. 
(1) Little or no mechanical vibration. 
(2) No corrosive gases. 
(3) Minimal temperature fluctuations and near normal temperature. 
(4) Not directly subject  to radiant heat. 
(5) Not subject  to strong electromagnetic field. 
(6) No direct exposure to water. 
 

 

       

WIRING 

 

  Wiring precautions 

While wiring take the following precautions. 

(1)  Field wiring to the instrument, should be placed so as to avoid blocking the air flow, yet 

 Provide a suitable service loop to allow easy removal of unit with wiring attached. 

(2)  Wires should be tied to maintain an order in the event they must be disconnected for 

 Any reason. 

(3)  For connecting the wire  to the terminals, we recommend use of crimp terminal lugs with  

Insulated sleeves. 

(4)  Route the input circuit wiring away as possible from the power and ground circuits to avoid  

Noise pickup. 

(5)  Use proper-shielded wire to avoid electromagnetic interference. 

 

 
 
 
 
 
 
 
 
 
 
 

                                  

 

Summary of Contents for TPLR-120 Series

Page 1: ...SCREEN PAPERLESS RECORDER TPLR 120 Series TEMPSEN DEVICES Plot No 2 3 Balaji Nagar 4th Street Mettukuppam Thoraipakkam Chennai 600097 Tele fax 91 44 24581758 Mobil 91 9841201758 Customer Care 91 9841...

Page 2: ...NSTALLATION Installation Location Install the control panel in a location that meets the following criteria 1 Little or no mechanical vibration 2 No corrosive gases 3 Minimal temperature fluctuations...

Page 3: ...B 0 to 1820 C 4 C RTD Base Accuracy 0 2 or 0 5 C 1 F Resolution 0 1 C 2 or 3 wire connection Cable compensation to 50 ohm Open and short circuit detection Type Range C Accuracy C 100 ohm Pt 385 200 t...

Page 4: ...pacity of above specified range provides a wide range of application in data storage for all channels individually Recording data on storage media Using the Setup menu the user can log the data in int...

Page 5: ...1 Compliant Software Web server Based Software Safety and Environmental Operating Range 0 C to 60 C 10 to 90 RH non condensing Dimension Bezel dimension 195 H x 300 W x 5mm above panel Unit dimension...

Page 6: ...es net Page 6 OPERATING PARAMETER SETTING Switch ON the device the following display will show the channel readings It will take a few seconds CONFIGURATION SETTING Click CONFIG in the display Enter t...

Page 7: ...ORDER www tempsendevices net Page 7 After entering the password the setting screen will be displayed as shown below TIME DATE SETTINGS In Setting SET Real Time Clock Set the real time date details Cli...

Page 8: ...www tempsendevices net Page 8 LOG TIME SETTINGS In Setting SET Log Time Set the Log Time Of The Logger Click Ok to save the settings PASSWORD SETTINGS In Setting Click SET Password this feature is use...

Page 9: ...range from the specified values Low 999 High 9999 RANGE Set the range with respect to the Sensor type specification REF PAGE NO 3 OFFSET Set the offset range from 999 to 999 Default set 0 DECIMAL Set...

Page 10: ...front panel of the Logger In Setting Click COPY Memory this feature is used to copy the Logger memory in to the Pen Drive If USB 2 0 drive is not inserted in the drive an error screen PEN DRIVE PROBLE...

Page 11: ...n Ink jet printer through the PRINTER PORT provided in the back panel of Logger In Setting Click PRINT Memory the entire memory will be printed GRAPH After completing all the Settings Click HOME icon...

Page 12: ...RMINAL DETAILS ID NUMBER In Setting ID NUMBER SETTING for Multi Logger Software DATA LOGGING OFF Logging Off The Data Logger Click HOME icon in the Setting screen In Setting DATA LOGGING OFF Input Ter...

Page 13: ...per terminals Connecting the supply to the wrong terminals may damage the unit permanently 2 Check the display whether it shows the actual value properly If yes follow step 3 if no check the sensor In...