7. Technical specifications 

Items 

Standards 

models 

Dual-mode infrared thermometer   

1.Applicable 
regulations and 
laws 

 
ASTM 1965/EN12470-5   

2.Temperature units 

/

, adjustable                                                                                                                                                             

℃ ℉

3.Measurement 
range 

Forehead temperature mode:32.0

-42.2

    / 

89.6

F – 107.9 

ear temperature mode:0.0

-100.0

    /32.0

F – 

212.0 

4.Precision   

±0.2

 /±0.4

5.Display resolution  0.1

/0.1

 

6.Latency Time 

1 second 

7.Abnormal state 
display 

LCD displays “L 

” if the measured temperature is 

below the minimum of measurement range. 
LCD displays “H 

” if the measured temperature is 

below the minimum of measurement range. 
LCD displays “Er1”if the temperature measurement 
circuit is abnormal (fault of SENSOR or the 
temperature measurement circuit), or the ambient 
temperature exceed 10

~40

 (50

-104

).

 

There shall be “ErC” if the calibration process is not 
completed or EEPROM is abnormal. 

8.Sound 

volume

50 db (the perpendicular distance from dB 

Volume sensor to thermometer is 10cm )   

9.Automatic 
shutdown function 

10s±1s 

10.Low-voltage 
display function 

The product shall display low-voltage signal if the 
voltage is below 2.51V±0.15V. 

11.Memory function  Memorize 20 groups of measured temperature. 

12.Current 
consumption 

I

stand-by

<2μA; I

working

<0.5mA; I

Buzzer on

<2mA

I

banklight

<15mA 

 

 

Contents 

 

1.The advantages of Dual-mode infrared thermometer   ..........................1 

2.Necessary safety instructions ................................................................1 

3.Instructions for product features.............................................................3 

4.How to measure the forehead temperature ...........................................3 

5.How to measure the ear temperature ....................................................3 

6.Instructions for display and operation ....................................................4 

7.Technical spcifications ............................................................................7 

8.After-sale service ....................................................................................8 

9.Security type ...........................................................................................8 

10.Authorized European Representative ..................................................8 

 
 

Pour Manuel en français 
 
Für Handbuch in Deutsch 
 
Per il Manuale in Italiano 
 

Para Manual en español 
 

 

                                     

WEBSITE

 

 

 

www.temp-ir.com 

 

 

 

 

 

Summary of Contents for Dual-Mode Infrared Thermometer

Page 1: ...To see our TempIR range of products and for customer service visit www temp ir com TempIR Dual Mode Infrared Thermometer Instruction manual www temp ir com 0482 ...

Page 2: ... 15 95 RH 16 Type of measuring Applicable for forehead temperature and ear temperature 17 battery Changeable for two 1 5V triple AAA batteries 18 Battery life More than 3000 times 19 Accuracy for clinical test The maximum allowable error for clinical test is specified in the formula below 0 3 0 6 for 95 Among which T1 and T2 represent temperature value for thermometer under test respectively Tref ...

Page 3: ...or the temperature measurement circuit or the ambient temperature exceed 10 40 50 104 There shall be ErC if the calibration process is not completed or EEPROM is abnormal 8 Sound volume 50 db the perpendicular distance from dB Volume sensor to thermometer is 10cm 9 Automatic shutdown function 10s 1s 10 Low voltage display function The product shall display low voltage signal if the voltage is belo...

Page 4: ...spital The cooperation with designated hospitals is subjected to precise clinical verification with the support of extensive clinical data and professional medical experts 2 Necessary safety instructions The device is not used for newborn baby 6 The LCD shall only display and M signal with M signal twinkling if there is no test data silence C F conversion LCD display How to change TempIR dual ther...

Page 5: ...instructions specified in cleaning and storage Please do not use the product if the temperature sensor or the Dual mode infrared thermometer shows any sign of damage Do not try to repair the product if it is damaged Please contact Customer Service Dual mode Infrared Thermometer consists of precision parts with high quality Please avaoid sharp shocks to or dropping the thermometer Do not twist the ...

Page 6: ...r it is suggested to wait for more than 30 minutes and please follow the rule 2 7 If the person having temperature takenis moved to another room or area it is suggested to wait more than 10 minutes and please follow the rule 2 8 Do not hold Dual mode Infrared Thermometer for long time as it is highly sensitive to heat Dual mode Infrared Thermometer has undergone clinical test it is safe and accura...

Reviews: