Maintenance Procedures Continued
Page 14
CARBURETOR
All carburetors comply with federal & state regulations and are preset by the engine
manufacturer. Engine performance may differ at various altitudes and climates. If you
feel that the carburetor on your blower needs adjusting contact Tempest or your local
engine dealer.
EMISSION CONTROL SYSTEM
State regulations require that all manufacturers of gas powered engines furnish written
instructions describing the Operation and Maintenance of the emission control systems.
These instructions vary depending on engine type. Please refer to your engine Opera-
tion and Maintenance Owners Manual under the heading “Emission Control Systems”
for specific information and instructions.
MAINTENANCE SCHEDULE
EVERY USE
- CHECK ENGINE OIL
- INSPECT BLOWER FOR DAMAGE AND FIX IF ANY
NEW BLOWER - FIRST THREE HOURS
- CHANGE ENGINE OIL
- TENSION BELT(S)
EVERY MONTH OR 10 HOURS
- CLEAN AIR FILTER
EVERY MONTH OR 25 HOURS
- INSPECT & CLEAN ENGINE HOUSING
- TIGHTEN/REPLACE ANY LOOSE OR MISSING PARTS
EVERY MONTH OR 50 HOURS
- CHANGE ENGINE OIL
EVERY MONTH OR 100 HOURS
- INSPECT & CLEAN SPARK PLUG