DEC4 Firmware Updates
From time to time Tempest may introduce new DEC4 firmware for feature enhancements and bug fixes. Please note that the
main System Control Board (SCB) and the various optional daughter boards each have their own firmware, and it will be good
practice to update all firmware in an enclosure for optimal performance and interoperability.
System Control Board firmware may be updated DIRECTLY using JESE JUST software and a USB cable, or INDIRECTLY,
over an RDM network, using JESE GETSET software and a JESE RDM-TRI interface.
Fan board firmware is extremely simple and is unlikely to require updating.
RS485 Board (51.485) firmware may be updated over an RDM network, using JESE GETSET software and a JESE RDM-
TRI interface.
All required files are available for download at
http://www.tempest.biz/tech-support.php?lang=en
Indirect Firmware Updates
Requirements
Windows Laptop / PC, Windows XP through Windows 10
A JESE RDM-TRI or RDM-TXI interface and USB connection (available from Tempest).
An installed version of the JESE GetSet RDM configuration utility.
A copy of the firmware file(s) to upload, available for download from
www.tempest.biz/tech_support
.
Powered Target DEC4 with 51.485 RS485 communication interface card.
Installation Procedure
1.
If not already installed, install a copy of GetSet.
To ensure that the correct USB drivers are loaded, the software should
be installed and the PC/Laptop re-started before connection to an RDM-TRI.